TROUBLESHOOTING
Page 11
PROBLEM
CAUSE
SOLUTION
Untreated water to
service
Open or defective bypass
Close or replace bypass
Appliance in regeneration
Wait until regeneration finishes or manually
advance regeneration to end
Excessive water usage
Initiate regeneration manually
Change in raw water hardness
Verify composition of incoming untreated water
and adjust regeneration frequency accordingly
Appliance fails to regenerate
Refer to problem “Appliance fails to regenerate”
Appliance fails to backwash properly
Refer to problem “Appliance fails to backwash
properly”
Valve body and timer out of synchronisation
Synchronize valve body and timer
Decreasing filter capacity of filter media
Clean or replace filter media
Loss of filter media
Refer to problem “Loss of filter media”
Leak at riser tube
Verify that riser tube is seated correctly and is not
cracked
Low levels of
contaminant in treated
water
Bypass not completely closed
Close bypass
Excessive service flow rate
Lower service flow rate
Increase filter capacity by increasing volume of filter
media
Leak at riser tube
Verify that riser tube is seated correctly and is not
cracked
Appliance fails to
regenerate
Faulty electrical supply
Verify electrical service (fuse, transformer,...)
Defective PCB
Replace PCB
Defective drive motor
Replace drive motor
Regeneration frequency not programmed
Program regeneration frequency
Loss of water pressure
Mineral or iron build-up in resin tank
Clean resin bed and control valve; increase
regeneration frequency
Plugged lower and/or upper distributor
Verify that distributors are free of debris
Crushed lower and/or upper distributor
Replace distributor(s)
Drain line from control
valve flows
continuously
Appliance in regeneration
Wait until regeneration finishes or manually
advance regeneration to end
Faulty electrical supply
Verify electrical service (fuse, transformer,...)
Defective drive motor
Replace drive motor
Defective micro switch
Replace micro switches
Defective PCB
Replace PCB
Valve body and timer out of synchronisation
Synchronize valve body and timer
Loss of filter media
Lower and/or upper distributor damaged
Replace distributor(s)
Leak between riser tube and upper distributor
Verify that riser tube is seated correctly and is not
cracked
Appliance fails to
backwash properly
Low operating pressure
Check operating pressure; must be higher than 2,0
bar
Insufficient water supply
Check water supply (flow rate/dynamic pressure)
Restricted drain line
Verify drain line for kinks or restrictions
Excessive build-up of impurities in pressure tank Clean or replace filter media and control valve;
increase regeneration frequency
Plugged backwash flow control
Clean or replace backwash flow control
Plugged top or bottom distributor
Verify that top and bottom distributor are clean and
slots are not clogged by iron or other impurities
Filter media is completely ‘caked’ (solid block)
Replace filter media and reduce regeneration
interval
Control valve cycles
continuously
Defective micro switch
Replace micro switches