Operating the Equipment Locally
3.6.1.1
DVB-S2 Input Option Card TT1290/HWO/DVBS2/IF/CONST
The DVB-S2 demod option TT1290/HWO/DVBS2/IF/CONST offers three
L-band inputs plus an IF input. If this input option card is fitted in the receiver then
note that Menu 2.3.5 sets the IF input frequency. LNB Frequency, Satellite
Frequency and LNB Power parameters are not applicable for this input.
The DVB-S2 demod option TT1290/HWO/DVBS2/IF/CONST also offers a
constellation output in DVB-S2 mode. This output can be enabled for each L-
band/IF input from the menu 2.3.X.6. Enabling this mode disables the demodulator
transport stream rendering the receiver unable to decode a service.
3.6.2
Telco Receiver – RX1290/HWO/G703
steps through the set-up procedure of the Telco Receiver using
Menu 2 Input, and the TTV G.703 input.
Table 3.7 Setting Up the TTV G.703 Interface
Step Action
Result
1
Connect the cable to the TTV
G.703 input.
2
Power up the unit and navigate
to Menu 2 Input.
Accesses the Input menu.
3
Press the
Right
pushbutton to
access Menu 2.3.
Selects the G.703 menu.
4
Navigate to INTERLEAVER
(Menu 2.3.3), then press
Edit
.
Select Enable or Disable, then
press
Save
.
Sets the required interleaving.
5
Navigate to SIGNAL LEVEL
(Menu 2.3.4), then press
Edit
.
Select Normal or Low, then
press
Save
.
Sets the unit sensitivity to the input signal level.
6
Navigate to REED-SOLOMON
(Menu 2.3.2), then press
Edit
.
Select ENABLE, then press
Save
.
Enables FEC functionality.
7
Return to Input Menu 2, it should
display the current status. If
status is NOT LOCKED, verify
that the cable is properly
connected and that all values
have been entered correctly.
EN/LZT 790 0003/2 R1A
3-11
Summary of Contents for RX1290
Page 22: ...Introduction EN LZT 790 0003 2 R1A 1 14 BLANK...
Page 42: ...Operating the Equipment Locally EN LZT 790 0003 2 R1A 3 4 BLANK...
Page 68: ...Operating the Equipment Remotely EN LZT 790 0003 2 R1A 4 2 BLANK...
Page 72: ...Operating the Equipment Remotely EN LZT 790 0003 2 R1A 4 6 BLANK...
Page 74: ...Alarms EN LZT 790 0003 2 R1A 5 2 BLANK...
Page 88: ...Preventive Maintenance and Fault finding EN LZT 790 0003 2 R1A 7 2 BLANK...
Page 142: ...Technical Specification EN LZT 790 0003 2 R1A B 28 BLANK...
Page 146: ...Menus EN LZT 790 0003 2 R1A C 4 BLANK...
Page 153: ...Menus Menus EN LZT 790 0003 2 R1A C 11 EN LZT 790 0003 2 R1A C 11...
Page 168: ...Menus EN LZT 790 0003 2 R1A C 26 BLANK...
Page 170: ...Language Abbreviations EN LZT 790 0003 2 R1A D 2 BLANK...