Power System
Characteristic
Description
Voltage
90–275 V AC
(1)
Frequency
45–65 Hz
Maximum inrush current
30 A (1–30 ms)
Maximum AC power, RBS 2206
4 × 1.4 kW
Maximum AC power, RBS 2206 V2
3 × 1.7 kW
Non-destructive range
0–275 V AC
(1) Install external filter and stabilizer if the requirement is not met.
RBS 2206 AC Fuses
Table 10
Fuse Specifications
Minimum for Safe
Function
Recommended for
Maximum Selectivity
Maximum Allowed
Fuse Rating
4 × 10 A
(1)
4 × 16 A
4 × 20 A
(1) For 200–250 V range only.
RBS 2206 V2 AC Fuses
Table 11
Fuse Specifications
120–127 V AC
(Nominal)
200–250 V AC
(Nominal)
Maximum Allowed
Fuse Rating
3 × 16 A
3 × 10 A
3 × 16 A
External Earth Fault Circuit Breakers
If external earth fault (ground fault) circuit breakers are used, then the
recommended minimum trip value is 100 mA.
8.2
+24 V DC Power
Table 12
+24 V DC Power Requirements
Characteristic
Description
Nominal
+24 V DC
Default
+27.2 V DC
Range
+20.5 to +29.0 V DC
Non-destructive range
+0 to +32 V DC
Inrush current
Max. 500 A (0.1–10 ms)
27
19/1551-LZA 701 0001 Uen PG1
|
2010-10-08