1/4-Core Ring (MSP line protection)
Figure 7-3: 1/4 Core Ring (MSP line protection
STM-1/4
MSP
OMS1200 STM1/4
WORKER
PROTECTION
WORKER
PROTECTION
A
B
EAST
WEST
LINE
LINE
LINE
LINE
In this example shown in Figure 7-3 MSP is configured on the STM-1/4 core card. The
Core B card acts as a Protection card and does not carry normal worker traffic.
7.2.2.2 Tributary
Cards
In addition to the rules in Section 7.2.2.1, the following slot positions must apply where
generic tributary cards are used.
Generic tributary cards are located in numerically adjacent slots, with the protection
card in the next available slot to the right, jumping the core and protection cards and
the blank slot. Generic tributary cards can be arranged in groups, with each group
having its own generic tributary card protection. See Table 7-4.
Rules
•
Unprotected generic Trib cards can be fitted in any generic Trib slot.
•
For 1+1 protection groups the protection trib must be fitted in the next
generic trib slot to the right of the worker