CONFIGURATION
LBI-38988
Rev. B
23
3. Verify that front panel LEDs L6 and L7 are
flashing, as shown in Table 6. This indicates the
GETC is ready for programming.
Table 6 - Indicators in Programming Mode Using J104
LED Indicators
L1
L2
L3
L4
L5
L6
L7
Programming Mode
❍
❍
❍
❍
❍
❉
❉
Legend:
❍
= OFF
●
= ON
❉
= FLASHING
4. Proceed with the Personality programming as
described in TQ-3357.
5. After saving the personality and downloading it
into the GETC, perform an operational checkout
of the GETC.
S4
S3
S2
S1
L1
L2
L3
L4
L5
L6
L7
T1
T2
U18
R1
1
1
1
1
1
U19
U3
U2
U1
U4
J3
J49
J27
J10
J9
J8
J5
J19
J7
TP107
U1
U2
Software Disk
TQ3357 V4 or later
To
COM Port
Turbo Board GETC Logic Board
J103 J104
J2
J3
Harness
19C337712G1
TQ-3360
TQ-3357
S2
S3
GETC Shelf 19D901868G3
Cable
Figure 7 - System Hook-Up Using J104
Summary of Contents for EDACS Station GETC1e 19D901868G3
Page 1: ...LBI 38988B ericssonz ericssonz Configuration Manual EDACS Station GETC1e 19D901868G3 and G4...
Page 34: ...LBI 38988B INTERCONNECT DIAGRAMS 34 Rev B MASTR III STATION INTERCONNECT...
Page 37: ...LBI 38988 Rev B 37 GETC CABLE 19C336863G1 19C336863 Sh 1 Rev 4 19C336866 Sh 1 Rev 0...
Page 38: ...LBI 38988B 38 Rev B This page intentionally left blank...