Command Line Interface
142
1553-CNH 160 0787 Uen PA2 2005-09-23
Argements:
<
string
> -
type what must be displayed in the prompt
none –
used if nothing must be displayed in the pormpt
Default Setting
-
Command Usage
The command is used to change the command prompt to make it easier to
identify a node.
Example:
(config system
)# prompt ECN320-172-30-18-39
ECN320-172-30-18-39#
11.6.10.12 radius-server
An RADIUS Server must be defined when authentication is needed to ac-
cess an ECN 320. Several RADIUS Servers can be defined and they are
used in the order they are configured so that if the connection to the first on
the list fails, connection to the next will be tried. The use of RADIUS au-
thentication must be enabled, see section 11.6.10.1 on page 1.
Command level:
ecn330(config system)#.
Syntax
radius-server enable host <
ip_address
> [auth-port
<
port
>][timeout <
seconds
>][key <
string
>]
radius-server disable host <
ip_address
> [auth-port
<
port
>]
Arguments:
•
host <
ip_address
> -
The IP address of the RADIUS Server
that must be added or deleted from the list of RADIUS Servers.
•
auth-port <
port
> -
The port number (TCP), on which the cli-
ent must contact the RADIUS Server. The default value is 1812.
Summary of Contents for ECN320
Page 1: ...ECN330 and ECN320 User Guide...
Page 27: ...ECN Functions Features and HW 1553 CNH 160 0787 Uen PA2 2005 09 23 19 Figure 6 Fan Tray...
Page 60: ...Web interface 52 1553 CNH 160 0787 Uen PA2 2005 09 23 Figure 29 Lines Overview...
Page 62: ...Web interface 54 1553 CNH 160 0787 Uen PA2 2005 09 23 Figure 31 Alarm Log...
Page 173: ...Using a MIB Browser 1553 CNH 160 0787 Uen PA2 2005 09 23 165 Figure 46 Querying VLAN ID...
Page 187: ......