Most console-related configuration parameters should

be changed at the CEC/IMC Manager and  sent to the
console. Users of the  Editor program must understand the
CEC/IMC Manager should be the central point of
databasing and configuration for all  C3 Maestro consoles
connected to the CEC/IMC Digital Audio Switch. Changes
made locally via the  Editor program will override settings
previously made via the 

CEC/IMC Manager.

Correspondingly, changes made via the CEC/IMC Manager
will override settings previously made via the  Editor
program.

At the PC's standard keyboard, execute the  Editor

program by typing 

EDITOR

 followed by an <Enter> from

an MS-DOS prompt. The  current 

directory must be

C:\CONSOLE

. See the LBI-39056 for additional details on

the use of the Editor program.

Logic Board Interrupt (IRQ)

The  Logic Board's interrupt software configuration

must match the interrupt number set by DIP switch SW2
(hardware configuration) on the Logic Board. Refer to the
previous DIP switch configuration information in this
manual and LBI-39056 for details.

If necessary, use the Editor program to set the interrupt

as required and save the  change to the hard disk drive.
Most all systems will use interrupt 7 (IRQ7). This is the
factory (default) setting.

COM1 Serial Port Baud Rate

In C3 Maestro console systems, the  baud rate of the

COM1 serial port can operate at 19,200 or 9600 baud. The
19,200 setting is recommended. 9600 baud may be required
when a data modem is employed between the console and
the CEC/IMC.

If necessary, use the  Editor program to change the

baud rate. Save the  change to the hard disk drive. 19,200
baud is the factory (default) setting. See  LBI-39056 for
additional details.

Set-Up Titles

From the Editor program's "

USER PROFILE DATA

"

screen, enter the titles as required. These titles are
displayed on the  C3 Maestro's "Change Setup" notecards.
Ten (10) titles, each with thirty-one (31) alphanumeric
characters, are available. See  LBI-39056 for additional
details.

Call Director ID

Call Director ID is a secondary console ID number that

is only used for Call Director telephone patch operations.

The default value for this ID is zero (0) 

 no Call Director.

Valid Call Director ID range is 1 - 16382. The zero setting
should not be changed unless a Call Director is attached to
the console and  the console will be used for Call Director
patch operations. The ID resides in the unit/console ID
space and  it should therefore be a unique (unused) ID
number. Console ID and Call Director ID should never be
identical.

If using CEC/IMC firmware version 2.x (and earlier),

set the Call Director ID number from the Editor program's
"

CONFIGURATION DATA

" form. Save changes to the

hard disk drive. See LBI-39056 for complete details.

If using CEC/IMC firmware version 3.x (and later) the

Call Director ID setting should be made via the CEC/IMC
Manager's "

Console Hardware Configuration

"

option and then sent to the console.

Boom/Gooseneck Microphone Presence

C3 Maestro firmware/software version 2.x required the

Editor program to manually set the presence/absence of a
boom/gooseneck microphone. However, firmware/software
version 3.x and Logic Board Rev. B hardware automatically
sense the presence of a boom/gooseneck microphone via a
hardware line from the 

BOOM/GOOSE MIC

 connector.

Therefore, this item was removed from the Editor program
version 3.x, as it is no longer required. If using
firmware/software version 2.x, set this option using Editor
program version 2.x as required.

NOTE

All  boom  and  gooseneck mic connectors (male
DB-9) must have pins 2 and 3 jumpered together
so the sense circuit will be active when the mic is
connected to the Audio Matrix Board.

RUNNING THE C3 MAESTRO
APPLICATION PROGRAM

The C3 Maestro application program will

automatically start when the PC is powered up via the

CONSOLE

(.EXE) statement in the AUTOEXEC.BAT file.

After exiting the program, restart it again from the PC's
standard  keyboard by typing 

CONSOLE

 followed by an

<Enter> at the MS-DOS prompt. The  current directory
must be 

C:\CONSOLE

. In addition, the CONKEY.COM

program which is also run via the AUTOEXEC.BAT file at
boot-up, allows the  C3 application program to be quickly
restarted by simply pressing function key <F10>. In a new
console installation, after starting the program, databases

Summary of Contents for C3 MAESTRO LBI-39055

Page 1: ...c Audio ALC Enable Disable DIP Switch 6 I O Board 6 INTERCONNECTING THE EQUIPMENT 6 CEC IMC INTERCONNECTIONS 7 Control Data Link 7 Remote Console Interconnections Via A 4 Wire Modem 8 Audio Links 9 PE...

Page 2: ...TION 21 Console User Profile Configuration 21 System Manager Database Uploads 21 Console Privilege Lists 22 Saving Database Information 22 SYSTEM TESTS 22 LOW LEVEL TESTS 22 Recommended Test Equipment...

Page 3: ...ibed NOTE C3 Maestro application software version 3 0x requires C3 Maestro Logic Board firmware version 3 02 or later CEC IMC Controller and Audio Board firmware version 3 0x or later and CEC IMC Mana...

Page 4: ...sole system BOARD SET UP IMPORTANT NOTE Unless otherwise noted all procedures in this manual should be performed in the order presented LOGIC BOARD Normally the Logic Board is configured correctly and...

Page 5: ...stro console system ships from the factory If the console system is ordered with multiple unselect speakers 2 or 3 or with the Call Director patch option two Audio PA Boards are installed DIP switches...

Page 6: ...h SW1 on the Audio Matrix Board is used to independently enable or disable each microphone s automatic level control ALC circuit The switch has four 4 positions one for each mic that may be connected...

Page 7: ...d in most all installations it is used for co located console interconnections RS 232 has poorer noise performance than RS 422 and therefore it should never be used for cable runs more than 50 feet in...

Page 8: ...g 3002 data grade specifications must be employed between the CEC IMC and the C3 Maestro in a remote console installation Figure 8B shows typical control data interconnections for a remote console ins...

Page 9: ...recommended TABLE 5 CONSOLE TO CEC IMC BALANCED LINE AUDIO INTERCONNECTIONS STANDARD 6 POSITION 4 CONTACT RJ 11 PIN NUMBER AUDIO PA BOARD 6 POSITION 4 CONTACT RJ 11 PIN NUMBER TO FROM CEC IMC 1 none n...

Page 10: ...LBI 39055 10 Figure 8A CEC IMC To C3 Maestro Interconnections Co Located...

Page 11: ...LBI 39055 11 Figure 8B CEC IMC To C3 Maestro Interconnections Remote And Or RS 232...

Page 12: ...ole s application program Connect the standard PC keyboard to the PC in accordance with the manufacturer s instructions Video Display Monitor Interconnect the video display monitor s video cable to th...

Page 13: ...gooseneck microphone option CRMC3F or equivalent may be connected to the Audio Tower Mount the microphone in accordance with the instructions supplied With the gooseneck microphone the supplied male D...

Page 14: ...ector to the respective female DB 9 connector on the I O Board Volume Controller Box if used If the console system is equipped with speakers the Volume Controller Box must be used Typically it is loca...

Page 15: ...in LBI 39062 for audio signal output level specifications Figure 10 I O Board Recorder Terminal Block Pin Out Pager Input if used Pager connections are also located on a terminal block on the I O Boar...

Page 16: ...e considered LINE C and LINE D respectively Figure 7 shows modular jack locations LINE C if used for a second unselect speaker connects to CEC IMC CIM channel line 3 Call Director LINE D connects to C...

Page 17: ...into the CD This handset overrides all audio connections to the Audio Tower The operator talks directly to the phone via the handset instead of using the console s headset or mic speaker Dry contact...

Page 18: ...C CMOS SET UP PROGRAM C3 Maestro software is factory installed on the PC s hard disk drive and the software is configured properly for standard installations Therefore during a typical console configu...

Page 19: ...BLE 12 C3 MAESTRO PC FILE DIRECTORIES AND FILES ROOT DIRECTORY C CONSOLE DIRECTORY C CONSOLE UTILITY DIRECTORY C UTIL AUTOEXEC BAT CONFIG SYS COMMAND COM IO SYS MSDOS SYS AUXIO DAT CONFIG DAT CONKEY C...

Page 20: ...number that is only used for Call Director telephone patch operations The default value for this ID is zero 0 no Call Director Valid Call Director ID range is 1 16382 The zero setting should not be c...

Page 21: ...ser Profile configuration to the console 7 When the User Profile Successfully Written message is displayed return to the CEC IMC Manager main menu If an Unable to Write User Profile message appears or...

Page 22: ...ity to control the Audio Tower s audio matrix circuitry It also verifies the line coupling circuitry and the speaker amplifier circuitry Cross point audio matrix switches are controlled opened and clo...

Page 23: ...Speaker B If not send the LINE B input to the SPKR B output by typing the following command F2 6641 Enter Adjust the unselect speaker Speaker B volume knob up and down and verify the volume changes T...

Page 24: ...nd the CEC IMC The procedures assume all equipment has been interconnected and set up in accordance with the previous instructions presented in this manual Control Data Link The C3 Maestro console and...

Reviews: