IMPORTANT SAFETY INFORMATION (Cont.)

13.

 GROUNDING AND AC POWER CORD CONNECTION -To reduce
the risk of electrical shock use only a properly grounded outlet. The
charger is equipped with an electric cord having an equipment-ground-
ing conductor and a grounding plug. Be sure that the outlet is properly
installed and grounded in accordance with all local codes and ordi-
nances.

14.

DANGER - Never alter the AC cord or plug. If it will not fit in the
outlet, have a proper outlet installed by a qualified electrician. Im-
proper connection can result in risk of an electric shock.

15.

The Rapid charger 120 Vac line cord has a grounding plug that looks
like the plug illustrated in Figure 1. A temporary adapter, which looks
like the adapter illustrated in sketches B and C, may be used to connect
this plug to a two-pole receptacle as shown in sketch B if a properly
grounded outlet is not available. The temporary adapter should be used
only until a properly grounded outlet can be installed by a qualified
electrician.

16.

DANGER - Before using an adapter as illustrated, be certain the cen-
ter screw of the outlet plate is grounded. The green-color rigid ear or
lug extending from the adapter must be connected to a properly
grounded outlet--make certain it is grounded. If necessary, replace the
outlet cover plate screw with a longer screw that will secure adapter
ear or lug to outlet plate and make ground connection to grounded out-
let.

5

Summary of Contents for BML 161 51/022

Page 1: ...UNIVERSAL DESK CHARGER STANDARD RAPID Operator s Manual ericssonz TO PREVENT FIRE OR ELECTRIC SHOCK HAZ ARD DO NOT EXPOSE THIS PRODUCT TO RAIN OR MOISTURE WARNING...

Page 2: ...ent and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Copyright Ma...

Page 3: ...ry to burst and cause personal injury or damage 4 Do not expose charger to rain or snow 5 Do not use auxiliary equipment not recommended or sold by the manufacturer To do so may result in a risk of fi...

Page 4: ...ate charger with damaged cord or plug replace them im mediately 10 Do not operate charger if it has received a sharp blow been dropped or otherwise damaged in any way return it to a qualified service...

Page 5: ...grounding plug that looks like the plug illustrated in Figure 1 A temporary adapter which looks like the adapter illustrated in sketches B and C may be used to connect this plug to a two pole recepta...

Page 6: ...required be tween the bottom of the charger and the surface on which it sits Figure 1 Grounding Methods Due to the temperature characteristics of nickel cadmium batteries the batteries will not accep...

Page 7: ...50 volt fast blow Standard Charger not fused RECHARGE TIME Rapid Charger 1 hour Standard Charger 14 hours OPERATING TEMPERATURE RANGE 5 to 45 C 41 to 113 F DIMENSIONS H x W x D Height 4 4 inches 112 m...

Page 8: ...of fully charging the battery pack in 14 hours The Rapid Desk Charger has a built in power supply and plugs directly into a 120 Vac or 230 Vac power source The charger is capable of charging most batt...

Page 9: ...ound the top and bottom covers 2 RAPID DESK CHARGER Locate the Rapid Desk Charger on a desk or other flat surface near a 120 220 Vac 50 60 Hz source and plug into the outlet To insure adequate ventila...

Page 10: ...ARGER If both RED and GREEN indicators are blinking fast immediately unplug the charger and return it for service If left in this condition the battery maybe severely overcharged causing personal inju...

Page 11: ...e move and reinsert the battery Weak or Dead Battery The CHARGE indicator goes to continuous RED after the battery has an acceptable pre charge typically less than 10 minutes Cold or Hot Battery The i...

Page 12: ...FAST When both indicators are blinking fast either the output has a short circuit or an abnormal output condition exists CHARGE RED CONTINUOUS Indicates battery is charging at the selected charging ra...

Page 13: ...ed The proper charge current for long or short case battery packs is selected by the insert microswitch To charge the battery to maximum capacity let the battery pack charge for at least 14 hours 3 RA...

Page 14: ...attery pack excessively cooled by an environ mental condition Defective Battery Battery pack with one or more of the internal cells shorted On occasion when charging a new battery or a battery which h...

Page 15: ...nly 1 Power cable not plugged in securely 2 Defective wall cube Standard Charger only 3 Battery pack not properly installed in charger 4 Defective charger return to a qualified service shop for repair...

Page 16: ...1 800 368 3277 USA only or FAX 1 800 833 7592 Please provide the description and part number when ordering e g PCS sleeve BML 161 51 002 The following pages illustrate and identify the accessories and...

Page 17: ...044 Rapid Charger Power Supply F29 4R A9 0082 Rapid Charger Control Board F29 4R A9 0083 Standard Charger Board F29 4R A9 0086 Charger Sleeve M PA M PD MTL BML 161 51 001 PCS BML 161 51 002 M RK BML...

Page 18: ...r the Equipment covered under Paragraph B 3 and only during the first three 3 months following the date of sale to the Buyer Thereafter labor will be charged at prevailing rates To be eligible for no...

Page 19: ......

Page 20: ...AE LZT 123 1870 R1A Printed in U S A Ericsson Inc Private Radio Systems Mountain View Road Lynchburg Virginia 24502 1 800 528 7711 Outside USA 804 528 7711...