17. Care should be taken when placing the charger in service
to insure proper top and bottom ventilation. A minimum
of 1/4" is required between the bottom of the charger and
the surface on which it sits.
SPECIFICATIONS
VOLTAGE SOURCE
120 volt switch position
96-144 Vac, 50/60 Hz
230 volt switch position
176-264 Vac, 50/60 Hz
POWER CONSUMPTION
Rapid Charger
170 watts
Standard Charger
30 watts
FUSE RATING
Rapid Charger
F1 - 5 Amp 250 volt, fast blow
Standard Charger
F1 - 315 mAmp 250 volt, fast blow
F2 - 600 mAmp 250 volt, slow blow
RECHARGE TIME
Rapid Charger
1 hour
Standard Charger
14 hours
OPERATING TEMPERATURE RANGE
+5
°
to +45
°
C
(+41
°
to +113
°
F)
DIMENSIONS(HxWxD)
Height
4.6 inches (117 mm)
Width
12.4 inches (315 mm)
Depth
18.2 inches (461 mm)
WEIGHT
Rapid Charger
15.7 lb. (7.1 kg)
Standard Charger
15.1 lb. (6.8 kg)
NOTE
Due to the temperature characteristics of nickel-
cadmium batteries, the batteries will not accept a
full charge at temperature extremes. For maximum
capacity, recharge the battery pack at a room tem-
perature of 65
°
to 85
°
F, whenever possible.
Figure 1 - Grounding Methods
IMPORTANT SAFETY INFORMATION
LBI-38708
4
Summary of Contents for 344A3072P8
Page 17: ...INTERCONNECT DIAGRAM LBI 38708 STANDARD MULTI UNIT CHARGER 344A3072P9 3R M5 0041 17...
Page 18: ...LBI 38708 SCHEMATIC DIAGRAM STANDARD MULTI UNIT CHARGER 344A3072P9 4R M5 0039A 18...
Page 20: ...LBI 38708 INTERCONNECT DIAGRAM RAPID MULTI UNIT CHARGER 344A3072P8 3R M5 0040 20...
Page 24: ...LBI 38708 ILLUSTRATED PARTS BREAKDOWN STANDARD MULTI UNIT CHARGER 344A3072P9 2R K5 0024A 24...
Page 25: ...ILLUSTRATED PARTS BREAKDOWN LBI 38708 RAPID MULTI UNIT CHARGER 344A3072P8 2R K5 0022A 25...