SPECIFICATIONS*
Part No.
Nominal
Input Voltage (Vac)
P11,P12
P14
121
240
Input Frequency (Hz)
ALL
50/60
Input Current (Amps)
P11,P12
P14
4
2
Output Voltage (Vdc)
(From 0.5 to 13 Amperes)
All
13.8
Output Ripple (mV P-P)
@ 3 Amps
@ 13 Amps
All
All
50 (Maximum)
100 (Maximum)
Transient Response (Vdc)
(Except overcurrent condition)
All
11.5 - 16.0
Duty Cycle
All
20%: 1 minute ON, 4 minutes OFF
Size
All
4.6 X 4.75 X 12.5 inches
Weight
All
13.1 LBS
*
These specifications are intended primarily for the use of the service technician. Refer to the appropriate Specification Sheet for
complete specifications.
19A704647P1-P3
UL Approval
19A704647P11-P12
CSA & UL Approval (Pending)
19A704647P14
European Approval (Pending)
A thermal protection unit will automatically reduce the output voltage if the output is at maximum value for an extended period
of time at 13 amperes.
NOTE
This unit contains dangerous voltage levels. It is strongly recommended that defective units be returned to the manufacturer
for repairs.
If field repair is necessary, remove the input power and then use a load resistor to manually discharge each capacitor before
servicing the unit.
WARNING
LBI-38751
3
Summary of Contents for 19A704647P1
Page 11: ...OUTLINE DIAGRAM HEATSINK ASSEMBLY P C BOARD 13 VOLT POWER SUPPLY EARLIER VERSION LBI 38751 11...
Page 12: ...OUTLINE DIAGRAM PC BOARD LATER VERSION LBI 38751 12...
Page 13: ...OUTLINE DIAGRAM 13 VOLT POWER SUPPLY 19A70647P1 P3 P11 P12 P14 LBI 38751 13...
Page 14: ...SCHEMATIC DIAGRAM 13 VOLT POWER SUPPLY 19A70467P1 P2 P11 P12 LBI 38751 14...
Page 15: ...SCHEMATIC DIAGRAM 13 VOLT POWER SUPPLY 19A704647P3 P14 LBI 38751 15...