SPECIFICATIONS*
OUTPUT VOLTAGE
Transmit and Receive Simultaneously
13.2 Vdc
±
0.6 Vdc @ 29 Amps (F801B)
13.2 Vdc
±
0.6 Vdc @ 4 Amps (J801)
Receive only
< 16.0 Vdc @ 3 Amps (J801)
Transmit only
(For 225 watt PA option)
13.2 Vdc
±
0.6 Vdc @ 33 Amps (F801B)
INPUT VOLTAGE
121 Vac
±
20% (60 Hz version)
230 Vac
±
15% (50 Hz version)
INPUT FREQUENCY
60 Hz
±
2 Hz (60 Hz version)
50 Hz
±
2 Hz (50 Hz version)
Note: For every + 1.0% change in the input frequency, the output voltage will not vary more than + 1.6% from the
output voltage measured at the nominal input line frequency.
INPUT LINE SURGE PROTECTION
150 V rated MOV (60 Hz version)
275 V rated MOV (50 Hz version)
DUTY CYCLE
For 0-33 Amp output
100% (Continuous Duty)
OUTPUT VOLTAGE RIPPLE
< 100 mV p-p @ 25
°
C
< 200 mV p-p @ -30
°
C
OUTPUT TRANSIENT RESPONSE
Overshoot
Undershoot
Not to exceed 18 Volts
Not less than 11 Volts
EFFICIENCY
> 70% @ rated TX/RX load current and nominal line volt-
age
FUSE CAPABILITY
Input
10 Amp (60 Hz version)
(2) 5 Amp (50 Hz version)
Output
5 Amp (Low Current Port)
40 Amp (High Current Port)
DIMENSIONS (HxWxD)
5.25" x 19" x 10.35"
WEIGHT
45 lbs.
OPERATING ENVIRONMENT
-30
°
C To +60
°
C
*
These specifications are intended primarily for the use of the service personnel. Refer to the appropriate Specification
Sheet for the complete specificationsl
LBI-38550
3
Summary of Contents for 19A149978P1
Page 13: ...SCHEMATIC DIAGRAM 60 HZ POWER SUPPLY 19A149978P1 Rev 0 Rev A 289PS1 Sh 1 Rev 1 LBI 38550 13...
Page 14: ...SCHEMATIC DIAGRAM 60 HZ POWER SUPPLY 19A149978P1 Rev B 289PS11 Sh 1 Rev A LBI 38550 14...
Page 15: ...PARTS LIST LBI 38550 15...
Page 16: ...ASSEMBLY DIAGRAM 50 HZ POWER SUPPLY 19A149978P2 Made from 289PS2 Sh 2 Rev Q LBI 38550 16...
Page 17: ...SCHEMATIC DIAGRAM 50 HZ POWER SUPPLY 19A149978P2 289PS2 Sh 1 Rev H LBI 38550 17...