a
1.5"
min.
4"
min.
a
Construct metal stud wall with components shown below.
b
Go to "step 1", page 2 to determine ergonomic mounting height, then continue with "step c", below.
c
Mount lift chassis to wall as shown below, then proceed to "step 3", page 9.
12 gauge, 1.5" x 4" metal
backing - minimum
1"
1"
.76"
.76"
The design of the wall studs is by the engineer of record.
#12-14
fasteners
(fi ve per
angle
bracket)
2"x2"x18 gauge
steel angle
brackets x 4"
long (two per
cross member)
24 gauge metal
studs - minimum
#12-14 Hilti Kwik
Flex fasteners.
NOTE: Screws are
to be placed in the
vertical center of
the backing.
OSHPD
METHOD A
LIGHT GAUGE METAL STUD WALLS
c
b
2