![Ergonomic products N1A Series Specification And Installation Manual Download Page 4](http://html.mh-extra.com/html/ergonomic-products/n1a-series/n1a-series_specification-and-installation-manual_2422372004.webp)
950-089 N1A manual ver B
ergonomic products • 198 Airport Rd • Fall River, MA 02720 • 866-374-6487
16” InWall Comfort Station
Model N1A
PAGE 4
1 - SPECIFICATIONS CONT’D
HOT & COLD WATER
SUPPLY BY PLUMBER
14-1/4"
MIN
DRAIN & VENT INSTALLED
PER CODE BY PLUMBER
50-1/4"
MIN
1' - 8
1
2
"
26
1
2
"
8"
4"
1/2" COLD WATER
SUPPLY W/ SHUTOFF
1/2" HOT WATER SUPPLY
W/ SHUTOFF
1 1/2" DRAIN
PROVIDE ACCESS
PANEL
(IF REQ'D)
12"
11"
16"
52"
5
1
2
"
14
1
2
"
11
1
2
"
4-5/8"
50"
13"
3-7/8"
33
5
8
FINISHED FLOOR
52"
OPEN BACK
FOR ACCESS TO
PLUMBING
REMOVABLE
ACCESS PANEL
5
1
8
"
PLUMBING SPECIFICATIONS
Unit is supplied with Delta 570 Single Lever
Faucet and 1-1/4” 90 degree Tail-piece.
Plumber To Provide:
- 1/2” Hot and Cold domestic supply
lines with straight 1/4 turn-stop and 3/8”
compression
- 1-1/2” DWV with P-Trap as shown
Note: All height dimensions are referenced
ABOVE the FINISHED FLOOR (“AFF”).
When planning the rough opneing.
it is critical to measure from the
installed Finished Floor, or account
for its eventual depth if it is not yet
installed.
Product Dimensions
Site Planning