EZ 1000 Series II Melter Part Manual
Chapter 8 Troubleshooting
©2019 by Crafco, Inc. All Rights Reserved………………...………………………………..……………...Troubleshooting 8-28
8.3 Hose Troubleshooting
Symptom: Hose Does Not Heat
8.3.1
Step
Possible Cause
If . . .
1
Is the Material Temperature Display at or
above 275°F?
•
Yes, go to Step 2.
•
No, continue to allow the machine to heat.
(Make sure the Material dial and the Hot
Oil dial are set at operating temperatures.)
2
Is the red "HEATED HOSE" light "ON"?
•
Yes, go to
•
No, allow the machine to heat material to
275°F.
2a
Is the circuit breaker tripped?
•
Yes, reset the circuit breaker by pushing in
the button which has popped out.
•
NOTE
:
Fig. 8-11 Hose Circuit Schematic
while troubleshooting the hose electrical system.
Step
Possible Cause
If . . .
1
Is there 12Vdc between “BATT” terminal of
the generator and a nearby ground source
(lug on battery tray)?
•
Yes, go to Step 2.
•
No, go to Step 6.
2
Is there 24Vac between the white, green, and
black wires?
NOTE
:
Do this test inside the junction box.
Check between black and white, black and
green, and green and white.
•
Yes, go to Step 3
•
No, stop the engine, tighten the belt, restart
engine and recheck output voltage.
•
Still no, replace the generator.
2a
Check the three heating element wires (blue)
in the junction box for 30 Amps cold or 20-22
Amps hot.
NOTE
:
Always use a clamp-on amp meter to
perform this test. Each wire should have the
same amp reading (+/- 1 amp).
•
Yes, the hose should be working properly.
•
No, go to Step 3.
Table 8-25 Basic Visual Troubleshooting
Table 8-26 Electrical Troubleshooting
Summary of Contents for Crafco 46200EB
Page 1: ...Parts Manual 26458 Revision Q ...
Page 16: ......
Page 18: ......
Page 26: ......
Page 48: ......
Page 66: ......
Page 196: ......
Page 200: ......
Page 201: ......
Page 202: ... 2019 Crafco Inc ...