Fault, cause and remedy
37
1
2
3
4
5
6
7
8
9
10
11
5
Fault, cause and remedy
5.1 Fault
table
Faults
UV lamps do not switch on when the timer/control is actuated
UV lamps and fan do not switch on when the timer/control is actuated
Decorative lighting does not light
Sunbed gets too hot
One or more UV low pressure lamps do not light
Canopy does not stay in the upper or lower position
Cause
Remedy
refer to section
No power
Check whether the fuse/FI safety switch is switched on
4.3.1
Starter is defective/not plugged in correctly
Change starter/insert correctly
4.4.1 up to 4.4.3
Filter mats soiled
Change filter mats
4.5
Insufficient supply and exhaust air
Check supply and exhaust air
4.5
UV low pressure lamp is defective/not plugged in correctly
Change the UV low pressure lamp / insert correctly
4.4.1 up to 4.4.3
Low pressure lamp is defective/not plugged in correctly
Change low pressure lamp / insert correctly
4.4.4
Life of lamp assembly expired
Replace lamp assembly
4.4.1 up to 4.4.3
Lifting mechanism set incorrectly
Inform after-sales service
7
Summary of Contents for Classik 475
Page 2: ...Ergoline Pro Sunbed from the No 1 2 ...
Page 8: ...8 ...
Page 14: ...General 14 1 2 3 4 5 6 7 8 9 10 11 ...
Page 36: ...Maintenance 36 1 2 3 4 5 6 7 8 9 10 11 ...
Page 40: ...Fault cause and remedy 40 1 2 3 4 5 6 7 8 9 10 11 ...
Page 44: ...Technical data 44 1 2 3 4 5 6 7 8 9 10 11 ...
Page 46: ...After sales service 46 1 2 3 4 5 6 7 8 9 10 11 ...
Page 50: ...Warranty EU Conformity 50 1 2 3 4 5 6 7 8 9 10 11 ...
Page 53: ......