ergolet Charder User Instruction Download Page 5

ENVIRONMENTAL SAFETY

 

 

All  batteries  contain  toxic  compounds.  Disposal  of  batteries  should 
be  delegated  to  a  competent  organization,  complying  with  the 
deposit  of  Poisonous  Waste  Regulation  1972.  Please  do  not 
incinerate batteries. 

 

You  are  legally  obliged  to  hand  in  used  batteries/rechargeable 
batteries to a local collection point so that they can be disposed of in 
an environmentally-friendly way. When buying new batteries, select 
batteries low in harmful substances and no mercury (Hg), cadmium 
(Cd) or lead (Pb). 

 

This  product  is  not  to  be  treated  as  regular  household  waste,  but 
should  be  handed  into  an  electrical/electronic  equipment  recycling 
centre.  You  can  obtain  further  details  from  your  local  council,  your 
municipal waste disposal company or the firm which you purchased 
the product. 

 

CLEANING 

 

We  would  recommend  using  alcohol  based  wipes  or  similar  when 
cleaning the scales. 

 

Please do not use large amounts of water when cleaning the scales 
as this will cause damage to electronics, you should also refrain from 
using corrosive liquids or high pressure washers.

 

 

Always turn off the scale before cleaning.

 

 

MAINTENANCE

 

 

The  scale does  not  require any routine maintenance. However, we 
recommend  checking  the  scale’s  accuracy  at  regular  intervals.  The 
regularity of these checks is dependent on the level of use and the 
state of the scale. If any inaccuracies occur, please contact Ergolet.

 

 

 

 

Summary of Contents for Charder

Page 1: ...on This user instruction must be read before the medical scale is used This user instruction is intended for technicians installers therapists and other personnel in connection with the use servicing...

Page 2: ...2...

Page 3: ...ENVIRONMENTAL SAFETY 5 CLEANING 5 MAINTENANCE 5 WARRANTY LIABILITY 6 READING BEFORE USE 6 SPECIFICATIONS 8 PANEL INDICATION 9 KEY FUNCTIONS 10 FEATURE SETTINGS 11 OPERATION FLOW 11 SETTING UP YOUR SCA...

Page 4: ...ions for installation proper use and maintenance of the scale The manufacturer shall not be liable for damages arising out of failure to heed the following instruction When using electrical components...

Page 5: ...into an electrical electronic equipment recycling centre You can obtain further details from your local council your municipal waste disposal company or the firm which you purchased the product CLEAN...

Page 6: ...r use incorrect installation or commissioning by the owner or third parties natural wear changes or modifications incorrect or negligent handling overuse chemical electrochemical or electrical interfe...

Page 7: ...Angle Ball joints are assembled with load cells from factory It should not be twisted by user or in any other circumstance Misusage will cause unexpected danger We do not recommend building a scale i...

Page 8: ...00kg 400kg Division 0 1kg 0 2kg Display options 5 1 2 digits Weight Unit Kg Dimension 120 x 50 x 160 mm Power 1 5V AAA 6 batteries Operating temperature 0 C 40 C WARNING Only kg unit is approved by OI...

Page 9: ...9 PANEL INDICATION HOLD indicator NET weight Gross weight kg indicator...

Page 10: ...lift a person Key description ON OFF ZERO TARE Press to switch on and depress 3 seconds to switch off Press to reset if weight is within 2 of full capacity Press to tare the weight and acquire net we...

Page 11: ...Auto Off Time Adjustment The device will automatically off according auto off time setting Auto off setting time 120 sec 180 sec 240 sec 300 sec off Buzzer Adjustment Switching the buzzer ON and OFF O...

Page 12: ...mode when is displayed Step 3 Press HOLD to select which means AUTO OFF TIME is 180 seconds Step 4 Press ZERO to decide and return to mode and press HOLD to shift to setup mode Step 5 Press ZERO to e...

Page 13: ...kaline batteries Please read the following instruction before using the scale 1 Find the battery cover at the back side of the scale 2 Remove the battery cover 3 Take the battery case out 4 Installing...

Page 14: ...der limited when power on please increase the loading OVER LOAD or COUNTING ERROR The loading is over limit please reduce the loading and try again If the trouble still exists please call for service...

Page 15: ...ssible 5 Type B The patient is not separated from ground 6 Name of the manufacturer 7 Warning Only for authorized personnel 8 Read the user instruction 9 The scale is calibrated and therefore accurate...

Page 16: ...90230 OULU Finland Manufactured by Charder Electronic Co Ltd No 103 Kuo Chung Road Dah Li City Taichung Hsien Taiwan R O C Dealer Ergolet Taarnborgvej 12 C 4220 Korsoer Danmark Phone 45 70 27 37 20 Fa...

Reviews: