EG_GenLoc54e_1040_UG_002_UK
Page 75 / 86
Descriptions and non-contractual illustrations in this document are given as an indication only.
ERCOGENER reserves the right to make any modifications.
Dct_427_02
8.2.7
RESET signal
Table 61 : Conditions of use of RESET signal
Parameters
Conditions
Min.
Typ.
Max.
Unit
V
IL
Input Voltage
– Low
-0.3
0.8
V
DC
V
IH
Input Voltage
– High
2
3.3
V
DC
RIPU
Internal Pull-Up Resistor
5.38K
Ω
Figure 38 : Wiring scheme of RESET signal
The use of the RESET signal must pass through a transistor assembly or a logic contact.