Notes and safety instructions

This distance may be less according to 
the environment. For this reason you 
should check possible spacing between 
the luminaires prior to installation.
- ERCO GmbH hereby declares that the 
luminaires with Casambi control are 
compliant to Directive 2014/53/EU. 
Radio operation is implemented on 
frequency bands 2402 – 2480MHz with 
maximum transmission power of 4dBm. 
The complete text of the EU declaration 
of conformity is available at the follow-
ing internet address:  
www.erco.com/casambi-ce.

Mounting

- When using wallwashers and direc-
tional luminaires, ensure correct align-
ment of the luminaire.
- When handling the reflector use the 
enclosed protective glove.

Removal 

Remove the luminaire in reverse order.
Note: Carefully lift the luminaire out of 
the mounting ring using a screwdriver.

Flashing of the LED module 

It is normal for the LED module to 
flicker when switching on and off.

Dimming

Depending on the version, the luminaire 
can be dimmed via suitable dimmers 
(trailing edge).

Trailing edge dimmers

Follow the manufacturer’s installation 
instructions. For some products, the 
luminaire can only be switched on in the 
upper dimming range. Before installation 
and connection, check luminaire, control 
gear and dimmer combination for proper 
functioning of the dimmer, especially 
when using universal dimmers. 
The use of dimmers which are unsuitable 
for LED drivers can damage the lumi-
naire, control gear and/or the dimmer.

No responsibility is accepted for the 
use of dimmers that are unsuitable for 
the luminaire.

Cleaning

Always clean carefully using a soft 
cloth and a commercially available, 
ph-neutral, alcohol-free, non-abrasive 
cleaning agent.

Disposal 

 

In accordance with EU Directive 

 

WEEE (Waste Electrical and Elec-

tronic Equipment), luminaires must not 
be disposed of with other household 
waste. At the end of their life, lumi-
naires must be taken to the appropriate 
local facility available for the disposal 
or recycling of electronic products.

English

Follow the attached mounting
instructions.

 Read the instructions carefully 

 

      before installation and commis- 

 

     sioning!

 Leave the instructions for users/ 

 

      customers for future reference!

 Our updated product documen- 

 

      tation can be accessed at  

 

     www.erco.com/download.

General safety information

 

 Warning! 

   

Risk of electric shock! 

 

- Before carrying out maintenance and 
installation on the luminaire, discon-
nect from the mains supply and also 
from any other DALI control wiring, and 
ensure that all power is switched off.
- Never operate luminaires with damaged 
connection cables.

 

 

Caution!

     

Blue light hazard!

RG2

 Position the luminaire  

 

       

marked with one of two  

 

       

adjacent pictograms so 

that extended gazing into the luminaire 
from a distance of less than xm is not 
expected. Find the value for x in the 
included graphic installation instructions.

Attention!

- In case of damage or a defective LED 
module, the entire luminaire must be 
returned to the factory.
- When installing, always observe the 
national installation and accident pre-
vention regulations.

Intended use

The luminaire is suitable for use in dry 
interiors only.

Choosing the mounting location

 Luminaire not suitable for covering 

 

  with thermal insulation material.

- Lateral air space under EN 60598:
The lateral distance between the surface 
of the luminaire and any parts of the 
building must be no less than 50mm.
- Recess depth according to EN 60598:
Any necessary minimum distance 
between the uppermost surface of the 
luminaire and any parts of the building 
can be found in the mounting instruc-
tions.
- Position the luminaire so as to avoid 
operation in direct sunlight or near other 
sources of heat. High ambient tempera-
tures can reduce the life and efficiency 
of the control gear or LED module.

Electrical installation

- Position the control gear as far from 
the luminaire as possible. Avoid crossing 
cables.

- Do not disconnect the electrical con-
nection between the luminaire and con-
trol gear! This can cause damage to the 
luminaire and/or the control gear.
- For 3-circuit installation: to avoid any 
damage to the control gear, the neutral 
conductor must never be connected or 
disconnected during operation.

Overvoltage protection

ERCO uses electronic control gear with 
overvoltage protection in accordance 
with DIN EN 61547. If additional protec-
tion from spikes is required, e.g. when 
switching off inductive loads, separate 
overvoltage protection units should be 
installed.

Luminaire with DALI control gear

- All cables, materials and devices used 
must be suitable for mains voltage, as 
the DALI signal is not transmitted using 
safety extra low voltage (SELV).
- For general information on DALI, 
please go to:  
www.digitalilluminationinterface.org.

Push Dim

DALI luminaires whose DA connections 
are additionally marked “N” and “Push” 
can be controlled directly with a com-
mercially available push-button (N.O. 
contact). For details see  
www.erco.com/pushdim.

RGBW luminaires 

By combining red, green and blue colour 
mixing with warm white LEDs at diffe-
rent dimming levels, all colours, shades 
and colour temperatures can be crea-
ted. To control the colours via a DALI 
system with colour management, the 
signal input has a DALI interface with 
an address for the luminaire. When 
operated using a system without colour 
management, 3 addresses per luminaire 
are used.
The colour compensation guarantees 
that exactly the same colour of light is 
obtained from all controlled luminaires 
which have the same DALI control set-
tings.

Tunable white

Control of the tunable white component 
only via the DALI system with colour 
management (device type-8). Other sys-
tems can only dim but not control the 
light colour.

Luminaires with Casambi Bluetooth 
control

- For control of the luminaire you need 
a Bluetooth 4.0-capable smartphone or 
tablet and the Casambi app for iOS or 
Android downloadable for free in the 
specific app stores.
- You can couple up to 127 luminaires 
in a Casambi mesh network. This num-
ber can be increased via several parallel 
networks.
- Because the switching signal in a 
mesh network is transferred from lumi-
naire to luminaire, the spacing between 
two luminaires must not exceed 10m. 