General safety information

 

 Warning! 

   

Risk of electric shock! 

Before carrying out maintenance and 

installation on the luminaire, discon-

nect from the mains supply and ensure 

that all power is switched off.

Attention!

- Do not open the luminaire head. In 

case of damage or a defective LED 

module, the entire luminaire must be 

returned to the factory.

- Do not operate luminaires with dama-

ged or missing safety glass.

- When installing, always observe the 

national installation and accident pre-

vention regulations.

Intended use

The luminaire is suitable for both out-

door and indoor use.

Choosing the mounting location

 Luminaire not suitable for covering  

  

with thermal insulation material.

- Lateral air space under EN 60598:

The lateral distance between the surface 

of the luminaire and any parts of the 

building must be no less than 50mm.

- Recess depth under EN 60598:

No minimum distance is required bet-

ween the uppermost surface of the 

luminaire and any parts of the building.

- Position the luminaire so as to avoid 

operation in direct sunlight or near 

other sources of heat. High ambient 

temperatures can reduce the life and 

efficiency of the control gear or LED 

module.

Electrical installation

- The connector is prepared for 

through-wiring (looping in).

- For 3-circuit installation: to avoid any 

damage to the control gear, the neutral 

conductor must never be connected or 

disconnected during operation.

Overvoltage protection

ERCO uses electronic control gear with 

overvoltage protection in accordance 

with DIN EN 61547. If additional protec-

tion from spikes is required, e.g. when 

switching off inductive loads, separate 

overvoltage protection units should be 

installed.

Notes on corrosion protection 

Ensure that the powder coating is not 

damaged during installation or mainte-

nance work. Any damage, which becomes 

wet, can result in corrosion occurring. In 

aggressive environments, the installation 

and maintenance of all parts will require 

the appropriate protective measures. Che-

micals damage the corrosion protection.

Rotating oval flood  

The oval flood characteristic is rotated 

by positioning the whole luminaire. Dis-

mount the luminaire and adjust before 

reinstalling it.

Flashing of the LED module 

It is normal for the LED module to 

flicker when switching on and off.

Dimming

Depending on the model, the luminaire 

can be dimmed using a suitable dimmer 

(trailing edge).

Trailing-edge dimmers

Follow the manufacturer’s installation 

instructions. For some products, the lumi-

naire can only be switched on in the 

upper dimming range. Before installation 

and connection, check lumi naire, control 

gear and dimmer combination for proper 

functioning of the dimmer, especially 

when using universal dimmers. 

The use of dimmers which are unsuitable 

for LED drivers can damage the lumi-

naire, control gear and/or the dimmer.

No responsibility is accepted for the 

use of dimmers that are unsuitable for 

the luminaire.

Cleaning

Always clean carefully using a soft 

cloth and a commercially available, 

ph-neutral, alcohol-free, non-abrasive 

cleaning agent.

Take care not to damage the powder-

coating.

Cleaning the safety glass

Safety glass can be cleaned with clea-

ning agents that are also suitable for 

glass-ceramic cooking hobs.

Disposal 

 

In accordance with EU Directive

 WEEE (Waste Electrical and Electro-

nic Equipment), luminaires must not 

be disposed of with other household 

waste. At the end of their life, lumi-

naires must be taken to the appropriate 

local facility available for the disposal 

or recycling of electronic products.