Caution:

 Keep the container of grease away 

from children.

10. TO REPLACE THE BRUSHES NOT PROVIDED 

(See Fig.7, 8)

Disconnect the plug from the power supply.

Unscrew the carbon brush cap with screwdriver.

Remove the carbon brush. Check the length of the 

brush and replace if under 6mm. When brushes need 

replacement always renew both brushes, even if one 

is still more than 6mm long.

Completely screw down the carbon brush cap. 

Check that the tool is working. Before use, allow it 

run for a few minutes to enable the brushes to settle.

Warning!

 The carbon brushes must be replaced 

by the manufacturer, its service agent or similarly 

qualified persons in order to avoid a hazard.

  

WORKING HINTS FOR YOUR TOOL

1. Reduce the pressure on the drill bit when it is about to 

break through. This will prevent the drill from jamming. 

2. When drilling a large hole, first drill a pilot hole using 

a smaller drill bit.

3. Always apply pressure to your drill bit in a straight 

line, and if possible at right angles to the workpiece.

4. Never change the operating mode whilst the drill is running.

5. Do not apply excessive pressure to the tool when 

chiseling. Expressive force does not speed up the work.

MAINTENANCE

Remove the plug from the socket before carrying 

out any adjustment, servicing or maintenance.

There are no user serviceable parts in your power tool. 

Never use water or chemical cleaners to clean your 

power tool. Wipe clean with a dry cloth. Always store 

your power tool in a dry place. Keep the motor ventilation 

slots clean. Keep all working controls free of dust. 

Occasionally you may see sparks through the ventilation 

slots. This is normal and will not damage your power tool.

If the supply cord is damaged, it must be replaced 

by the manufacturer, its service agent or similarly 

qualified persons in order to avoid a hazard.

TROUBLESHOOTING

1. If your power tool does not start, check the plug on 

the power supply first.

2. If your hammer becomes too hot in use, set the 

hammer switch to the drill mode and allow your drill to 

operate at maximum speed without load for 2 minutes.

Summary of Contents for ERB575DRH

Page 1: ...1250W 6kg HAMMER DRILL ERB575DRH ERB575DRH...

Page 2: ...Original Instructions Version 1 0...

Page 3: ...ces caused by the jamming by securely holding the drill with both hands As this is a very powerful drill these forces are significant 2 ALWAYS ensure that the front handle is firmly affixed and secure...

Page 4: ...his guarantee does not affect your statutory rights This guarantee is only valid in the UK For further technical advice spare parts or repair service outside of guarantee please contact the customer h...

Page 5: ...pulling or unplugging the power tool Keep cord away from heat oil sharp edges or moving parts Damaged or entangled cords increase the risk of electric shock e When operating a power tool outdoors use...

Page 6: ...rts and any other condition that may affect the power tool s operation If damaged have the power tool repaired before use Many accidents are caused by poorly maintained power tools f Keep cutting tool...

Page 7: ...isk groups within this because of the dust that they breathe silica dust is not just a nuisance it is a real risk to your lungs Silica is a natural mineral present in large amounts in things like sand...

Page 8: ...asks that are specially designed to filter microscopic particles VIBRATION The European Physical Agents Vibration Directive has been brought in to help reduce hand arm vibration syndrome injuries to p...

Page 9: ...period on this tool Helping to minimise your vibration exposure risk ALWAYS use sharp chisels drills and blades Maintain this tool in accordance with these instructions and keep well lubricated where...

Page 10: ...Wear eye protection Wear dust mask Wear safety gloves Waste electrical products should not be disposed of with household waste Please recycle where facilities exist Check with your Local Authority or...

Page 11: ...1250W 6kg HAMMER DRILL ERB575DRH 1 2 3 4 5 6 7 8 9 10 11...

Page 12: ...COVER 4 ON OFF SWITCH 5 HAMMER OR DRILLING ACTION SELECTOR SWITCH 1 6 HAMMER OR CHISEL ACTION SELECTOR SWITCH 2 7 VARIABLE SPEED CONTROL 8 AUXILIARY HANDLE 9 DUST COVER 10 SPANNER 11 ACCESSORY KITS T...

Page 13: ...e LpA 90dB A KpA 3 0dB A A weighted sound power LwA 101dBA KwA 3 0dB A Wear ear protection when sound pressure is over 80dB A ACCESSORIES Auxiliary handle 1pc Depth gauge 1pc Dust cover 1pc Spanner 1p...

Page 14: ...o the handle Adjust it to the desired depth Rotate the locking screw clockwise to tighten 3 FITTING BITS See Fig 2 Clean the bit shank and apply grease before installing the bit Hold the rotary grip p...

Page 15: ...up for hammer drilling into masonry DRILLING FUNCTION 1 Press the lock button A and rotate the selector switch to make sign point to the triangle 2 Turn the hammer or drilling action selector switch p...

Page 16: ...ssory CHISEL FUNCTION 1 For chipping grooving or demolition operation press the lock button A and then rotate the selector switch make sign pointing to the triangle 2 Turn the hammer or drilling actio...

Page 17: ...apply pressure to your drill bit in a straight line and if possible at right angles to the workpiece 4 Never change the operating mode whilst the drill is running 5 Do not apply excessive pressure to...

Page 18: ...ad are coloured in accordance with the following code BLUE NEUTRAL Brown Live As the colours of the wires in the mains lead of this appliance may not correspond with the coloured markings identifying...

Page 19: ...EC Electromagnetic Compatibility Directive 2004 108 EC Restrictions of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment 2011 65 EU Waste Electrical and Electronic Equipm...

Page 20: ......

Reviews: