ELECTRICAL CONNECTIONS
The motor is supplies with a 2 Mtr long power cable with clamps for
Connection to the battery.
Red—Positive Pole (+) Black—Negative Pole (
-
)
Ensure correct voltage battery is being used to power unit. Maximum variation allowed
for voltage is ±5% of rated value. A start
-
stop switch is standard with a rated fuse for
motor protection.
30 Amp fuse—
12
volt 15 Amp fuse—
24
volt
It is the installers responsibility to make the electrical installation in accordance
with the applicable local codes and safety regulations.
START UP AND OPERATION
Ensure that amount of Diesel in suction tank is greater than amount to be pumped.
Never run the pump dry as serious damage could result and void the warranty.
(1)
Check voltage of power source is same as that of the pump.
(2)
Always connect rod terminal to + pole. Black terminal to
-
pole
(3)
Never touch different polarity terminals together as a spark may occur causing a
fire or explosion. Damage to pump motor also may occur.
(4)
Take the nozzle out from the holder checking it is closed.
(5)
Operate the starting switch. The bypass allows the pump to operate with a
closed nozzle for short periods of time. 30 seconds maximum.
(6)
Insert the nozzle into container or tank to be fitted.
(7)
Holding the nozzle firmly, operate the lever to dispense fuel.
(8)
Release nozzle lever to stop dispensing.
(9)
Switch the pump off and put nozzle back in the holder.
Pump duty cycle is for 30
minutes maximum. This
means that pump must be
allowed to cool for at least 30
minutes before using again. Failure to follow this direction could cause motor failure.
ATTENTION
In hot weather it is recommended to open the nozzle once the pump is stopped to
release stored pressure.
Likewise in extreme cold temperatures drain the hose and nozzle when not in use.
Failure to do this could cause overpressure due to expansion and damage the pump.
WARNING
This pump is for use with Diesel Fuel only.
Do not use for transfer of petrol, petroleum products or any other fluid with a
flash point below 55° C (130° F).
The motor is not of explosion proof type.
BT46 PARTS BREAKDOWN
POSITION
DESCRIPTION
ITEM CODE
QTY
1
ZINC PLATED SCREW CHC M5x8
140758
3
2
BYPASS KIT
142078
1
4
KIT VANES
142081
5
5
ZINC PLATED THREADED ROD M5 L.135
140836
2
6
ZINC PLATED NUT M5
140879
2
7
ZINC PLATED SCREW CHC M5x50
140764
2
8
ON/OFF SWITCH 12V 30A
140409
1
9
CABLE GLAND M20x1.5
140295
1
10
SWITCH CAP 12V
141531
1
11
CABLE WITH CLAMPS LG4M 2x2.5mm²
140227
1
12
MOTOR 12 V 5000T 140 W
141672
1
12
141673
MOTOR 24 V 5000T 140 W
1
13
PUMP BODY 12/24V
-
40L
141389
1
14
PUMP ROTOR
141827
1
15
STEEL COVER
141456
1
19
SHAFT KEY 3X3X10
141570
1
20
MINI FORK FUSE 30A 12 VOLT
140356
1
20
140357
MINI FORK FUSE 15A 24 VOLT
1
21
SEAL KIT
142082
1
22
142083
FACE O
-
RING KIT
3
IMPORTANT