ELECTRICAL CONNECTIONS

 

The motor is supplies with a 2 Mtr long power cable with clamps for 

 

Connection to the battery.

 

Red—Positive Pole (+)              Black—Negative Pole (

-

)

 

Ensure correct voltage battery is being used to power unit. Maximum variation allowed 

for voltage is ±5% of rated value. A start

-

stop switch is standard with a rated fuse for 

motor protection.

 

 30 Amp fuse—

12 

volt         15 Amp fuse—

24 

volt

 

It is the installers responsibility to make the electrical installation in accordance 

with the applicable local codes and safety regulations.

 

 

START UP AND OPERATION

 

Ensure that amount of Diesel in suction tank is greater than amount to be pumped. 

Never run the pump dry as serious damage could result and void the warranty.

 

(1)

 

Check voltage of power source is  same as that of the pump.

 

(2)

 

Always connect rod terminal to + pole. Black terminal to 

-

 pole

 

(3)

 

Never touch different polarity terminals together as a spark may occur causing a 

fire or explosion. Damage to pump motor also may occur.

 

(4)

 

Take the nozzle out from the holder checking it is closed.

 

(5)

 

Operate the starting switch. The bypass allows the pump to operate with a  

closed nozzle for short periods of time. 30 seconds maximum.

 

(6)

 

Insert the nozzle into container or tank to be fitted.

 

(7)

 

Holding the nozzle firmly, operate the lever to dispense fuel.

 

(8)

 

Release nozzle lever to stop dispensing.

 

(9)

 

Switch the pump off and put nozzle back in the holder.

 

 

 

 

Pump duty cycle is for 30 

minutes maximum. This 

means that pump must be 

allowed to cool for at least 30 

minutes before using again. Failure to follow this direction could cause motor failure.

 

ATTENTION 

 

In hot weather it is recommended to open the nozzle once the pump is stopped to 

 

release stored pressure.

 

Likewise in extreme cold temperatures drain the hose and nozzle when not in use. 

Failure to do this could cause overpressure due to expansion and damage the pump.

 

 

 

 

 

 

WARNING

 

This pump is for use with Diesel Fuel only.

 

Do not use for transfer of petrol, petroleum products or any other fluid with a 

flash point below 55° C (130° F).

 

The motor is not of explosion proof type.

 

BT46 PARTS BREAKDOWN

 

POSITION

 

DESCRIPTION

 

ITEM CODE

 

QTY

 

1

 

ZINC PLATED SCREW CHC M5x8

 

140758

 

3

 

2

 

BYPASS KIT

 

142078

 

1

 

4

 

KIT VANES

 

142081

 

5

 

5

 

ZINC PLATED THREADED ROD M5 L.135

 

140836

 

2

 

6

 

ZINC PLATED NUT M5

 

140879

 

2

 

7

 

ZINC PLATED SCREW CHC M5x50

 

140764

 

2

 

8

 

ON/OFF SWITCH 12V 30A

 

140409

 

1

 

9

 

CABLE GLAND M20x1.5

 

140295

 

1

 

10

 

SWITCH CAP 12V

 

141531

 

1

 

11

 

CABLE WITH CLAMPS LG4M 2x2.5mm²

 

140227

 

1

 

12

 

MOTOR 12 V 5000T 140 W

 

141672

 

1

 

12

 

141673

 

MOTOR 24 V 5000T 140 W

 

1

 

13

 

PUMP BODY 12/24V

-

40L

 

141389

 

1

 

14

 

PUMP ROTOR 

 

141827

 

1

 

15

 

STEEL COVER

 

141456

 

1

 

19

 

SHAFT KEY 3X3X10

 

141570

 

1

 

20

 

MINI FORK FUSE 30A 12 VOLT

 

140356

 

1

 

20

 

140357

 

MINI FORK FUSE 15A 24 VOLT

 

1

 

21

 

SEAL KIT

 

142082

 

1

 

22

 

142083

 

FACE O

-

RING KIT

 

3

 

  