www.prolight.co.uk
Spark Stream
User Manual
6
Button A – Stop output
Button B – Low continuous output
Button C – Medium continuous output
Button D – High continuous output
(
- Example of what the display will show)
Operating instructions
Wireless Remote Control:
Ensure the handheld remote is fitted with a good quality battery
(A23 12V Alkaline). Press the correct button as per the list below
to select the required mode of operation.
Operation:
Connect the sparks stream to a suitable mains outlet using the
PowerCON cable and switch the power switch to the on position.
After the unit has been powered up the spark machine will take
8 minutes to heat up to operating temperature. Whilst heating the
LED display will chase 4 red dots, once heated the 4 red dots on
the display will stop chasing and stay illuminated.
To set the DMX address press the
“FUNCTION”
button until
A001
is displayed. Now use the
“UP”
and
“DOWN”
buttons
to select between
A001
~
A512
.
To begin operation via DMX connect the fixture to a suitable DMX
controller via the 5-pin DMX input on the rear of the unit.
Pressing the
“FUNCTION”
button allows for the temperature to
be displayed.
To begin operation via the wireless remote press one of the
4 buttons on the wireless remote control (see below).
Care should be taken to ensure that the granules hopper is
not allowed to run empty. Running the machine empty can damage
the unit and void the warranty.
Isolate from the mains supply before refilling the granules hopper.
8.8.8.8
8.8.8.8
8.8.8.8
8.8.8.8
Wireless remote control
1 channel mode:
Channel
Value
Function
CH1
000-063
No function
064-127
Low output
128-195
Medium output
196-255
High output
Output height/time:
Button Output
Height Output Time (120g pouch)
B
Low output
2.5m
8 minutes (approx.)
C
Medium output 3.5m
7 minutes (approx.)
D
High output
5m
6 minutes (approx.)
~
-