background image

iRMMM=c~ãáäó=qÉêãáå~ä=fåëí~ää~íáçå=dìáÇÉ

Equipment Checklist

Power & Cable Connections

Stylus Pen

L5000 Family Terminal

(L5300 shown for illustration)

The 

iRMMM=c~ãáäó=qÉêãáå~ä=fåëí~ää~íáçå=dìáÇÉ provides basic 

terminal setup information.
Note: Images in this guide may not exactly match your device 

(e.g., contactless and communication modules are optional).
Additional accessories are available for purchase. Contact

your Equinox Sales Associate for specific options.
Upon receipt of the terminal, immediately change the default

Setup password. Changing the password can be done 

terminal by terminal or via download. For instructions on

changing the password, contact your Equinox Sales Engineer

or Equinox Technical Support at 1-877-497-3726.

Additional Accessories 

(Contact your Equinox Sales Associate for current information and availability.)

If required, remove plug from

round opening in stylus holder

(as shown) by pushing up from

underside. To insert, push plug

into round opening from above.

Insert the connector end of the

stylus pen (as shown).

Stand

Installation

If required, remove smart card

reader plug from wrapper. Insert

plug into smart card receptacle

slot (as shown).

Insert metal stand prongs into 3 stand

slots on underside of terminal. Slide

terminal firmly into place on stand.

Power Cord

(if provided)

N

L5000 terminal

O

If required, insert 12-24 volt Powered RS232

cable into RS232+POWER port (as shown).

Note: Power supply required for RS232 cable. See RS232

cable note in 

Additional Accessories, below.

If required, insert the USB cable into the USB

Host port (as shown).

Note: Supports connection of certain peripheral USB

devices to OS/FPE32.

P

If required, insert the 12-24 volt Powered USB cable

into the PUSB port (as shown).

Note: Port used to interface to another USB port on a PC or 

POS terminal.

RS232 + POWER port (standard)

Smart Card

Reader Plug

Q

If required, insert the cable into the 100 BASE-T

port (as shown).  

Note: Used to download images, for

HTMS support, or for enabling financial transactions using SSL

over the internet.

If required, insert cables into corresponding

Communication Module ports.

Note: Contact your Equinox Sales Associate for specific

Communication Module options.

100 BASE-T port (standard)

RS232 Cable

(P/N 810408-001)

To be used with Power Supply

(P/N 870066-004)

Powered USB Cable

12-volt (P/N 810349-001)

24-volt (P/N 810349-002)

Power Supply 

(P/N 870066-004)

Requires a Power Cord

Power Cord

(P/N 810003-007)

Contactless Reader 

Module

(P/N 020380-601E)

Communication 

Module 

(P/N 01036x-1xxE)

Smart Card 

Reader Plug

(P/N 600672-001)

Capacitive Activated 

Stylus Pen

(P/N 040367-001E)

Stylus Pen

Turn terminal over. If required, connect Power

Cord to Power Adapter. Insert Power Adapter

Cable connector into POWER port and then

turn counter-clockwise to lock. Insert the

Power Cord plug into wall receptacle.

Standard ports:

mrp_

NMM=_^pbJq=bíÜÉêåÉí

opOPOHmltbo

rp_=eçëí

bíÜÉêåÉí

q~áäÖ~íÉ

J=mçïÉê=çîÉê=bíÜÉêåÉí=EmçbF=

USB Host port (standard)

Power

port

Stylus

Holder

Stand

Slots

Stylus Holder Plug

(P/N 600725-002E)

Smart Card Reader Plug

P/N 600672-001

S

Arrange installed cables through opening at back of terminal.

Insert bracket and press into grooves to left and right of open-

ing to secure.  If done correctly, the PWR label aligns with the

POWER label on the terminal (as shown). Note: Position

largest opening in bracket toward left side of opening.

Ethernet port

(optional)

Cable

Management

Bracket

R

N

Stylus Pen

Connector

Standard

ports

Powered USB port (standard)

T

U

Optional

Communication

Module

Ports available on

Communication Module:

Tailgate port 

(12V powered, optional)

Wrap stylus cable along back of 

terminal and secure in retention clip

(as shown).

Smart Card

Reader Plug 

(if provided)

Cable Management

Bracket

Power Supply

(if provided)

Retention Clip

PWR

Label

O

Cable Lock

If required, insert customer-

provided cable lock into

Kensington

®

slot. Loop cable

around permanent object to

secure terminal in place.

Slot

Cable Lock

Cable Management

Bracket

(P/N 600671-001)

Base

Cap

Applicable to L5200 and L5300

Stylus Holder

Plug

Stylus Holder

Plug

Stylus Holder Plug

P/N 600725-002E

`~ÄäÉ

mLk=MNMPSMJNMOb=ëÜçïå=Ñçê=áääìë

íê~íáçå

t^okfkdW=

Prior to using this device, read these instructions carefully for important 

information, including any use restrictions that may apply.
• Use only the power adapter provided with this device. Non-

compliant power adapters may damage this device, thereby 

invalidating its warranty.

•  This device must be connected to the correct electrical supply. 

Connection to an inappropriate supply may damage or destroy this 

device.

•  Do not power ON this device in a flammable atmosphere, such as a 

petrol station, chemical depot, etc.

•  Only operate this device within the temperature range of 0

°

C - 45

°

(32

°

F - 113

°

F).

•  Do not expose this device to temperatures above 60

°

C (140

°

F).

•  Do not use this device if it is visibly damaged.

•  Do not disassemble, incinerate, or crush this device.

•  Keep this device out of reach of children and pets.

`^rqflkW

Users of this device are cautioned to only use accessories and peripher-

als approved by Equinox Payments. Changes to this device or use of

accessories other than recommended or approved by Equinox Payments

may result in the loss of the user’s authority to operate the device.

Powered Supply Adapter

Right Angle

(P/N 810411-001)

USB Cable 

(P/N 810371-012)

Reviews: