iRMMM=c~ãáäó=qÉêãáå~ä=fåëí~ää~íáçå=dìáÇÉ
Equipment Checklist
Power & Cable Connections
Stylus Pen
L5000 Family Terminal
(L5300 shown for illustration)
The
iRMMM=c~ãáäó=qÉêãáå~ä=fåëí~ää~íáçå=dìáÇÉ provides basic
terminal setup information.
Note: Images in this guide may not exactly match your device
(e.g., contactless and communication modules are optional).
Additional accessories are available for purchase. Contact
your Equinox Sales Associate for specific options.
Upon receipt of the terminal, immediately change the default
Setup password. Changing the password can be done
terminal by terminal or via download. For instructions on
changing the password, contact your Equinox Sales Engineer
or Equinox Technical Support at 1-877-497-3726.
Additional Accessories
(Contact your Equinox Sales Associate for current information and availability.)
If required, remove plug from
round opening in stylus holder
(as shown) by pushing up from
underside. To insert, push plug
into round opening from above.
Insert the connector end of the
stylus pen (as shown).
Stand
Installation
If required, remove smart card
reader plug from wrapper. Insert
plug into smart card receptacle
slot (as shown).
Insert metal stand prongs into 3 stand
slots on underside of terminal. Slide
terminal firmly into place on stand.
Power Cord
(if provided)
N
L5000 terminal
O
If required, insert 12-24 volt Powered RS232
cable into RS232+POWER port (as shown).
Note: Power supply required for RS232 cable. See RS232
cable note in
Additional Accessories, below.
If required, insert the USB cable into the USB
Host port (as shown).
Note: Supports connection of certain peripheral USB
devices to OS/FPE32.
P
If required, insert the 12-24 volt Powered USB cable
into the PUSB port (as shown).
Note: Port used to interface to another USB port on a PC or
POS terminal.
RS232 + POWER port (standard)
Smart Card
Reader Plug
Q
If required, insert the cable into the 100 BASE-T
port (as shown).
Note: Used to download images, for
HTMS support, or for enabling financial transactions using SSL
over the internet.
If required, insert cables into corresponding
Communication Module ports.
Note: Contact your Equinox Sales Associate for specific
Communication Module options.
100 BASE-T port (standard)
RS232 Cable
(P/N 810408-001)
To be used with Power Supply
(P/N 870066-004)
Powered USB Cable
12-volt (P/N 810349-001)
24-volt (P/N 810349-002)
Power Supply
(P/N 870066-004)
Requires a Power Cord
Power Cord
(P/N 810003-007)
Contactless Reader
Module
(P/N 020380-601E)
Communication
Module
(P/N 01036x-1xxE)
Smart Card
Reader Plug
(P/N 600672-001)
Capacitive Activated
Stylus Pen
(P/N 040367-001E)
Stylus Pen
Turn terminal over. If required, connect Power
Cord to Power Adapter. Insert Power Adapter
Cable connector into POWER port and then
turn counter-clockwise to lock. Insert the
Power Cord plug into wall receptacle.
Standard ports:
-
mrp_
-
NMM=_^pbJq=bíÜÉêåÉí
-
opOPOHmltbo
-
rp_=eçëí
-
bíÜÉêåÉí
-
q~áäÖ~íÉ
J=mçïÉê=çîÉê=bíÜÉêåÉí=EmçbF=
USB Host port (standard)
Power
port
Stylus
Holder
Stand
Slots
Stylus Holder Plug
(P/N 600725-002E)
Smart Card Reader Plug
P/N 600672-001
S
Arrange installed cables through opening at back of terminal.
Insert bracket and press into grooves to left and right of open-
ing to secure. If done correctly, the PWR label aligns with the
POWER label on the terminal (as shown). Note: Position
largest opening in bracket toward left side of opening.
Ethernet port
(optional)
Cable
Management
Bracket
R
N
Stylus Pen
Connector
Standard
ports
Powered USB port (standard)
T
U
Optional
Communication
Module
Ports available on
Communication Module:
Tailgate port
(12V powered, optional)
Wrap stylus cable along back of
terminal and secure in retention clip
(as shown).
Smart Card
Reader Plug
(if provided)
Cable Management
Bracket
Power Supply
(if provided)
Retention Clip
PWR
Label
O
Cable Lock
If required, insert customer-
provided cable lock into
Kensington
®
slot. Loop cable
around permanent object to
secure terminal in place.
Slot
Cable Lock
Cable Management
Bracket
(P/N 600671-001)
Base
Cap
Applicable to L5200 and L5300
Stylus Holder
Plug
Stylus Holder
Plug
Stylus Holder Plug
P/N 600725-002E
`~ÄäÉ
mLk=MNMPSMJNMOb=ëÜçïå=Ñçê=áääìë
íê~íáçå
t^okfkdW=
Prior to using this device, read these instructions carefully for important
information, including any use restrictions that may apply.
• Use only the power adapter provided with this device. Non-
compliant power adapters may damage this device, thereby
invalidating its warranty.
• This device must be connected to the correct electrical supply.
Connection to an inappropriate supply may damage or destroy this
device.
• Do not power ON this device in a flammable atmosphere, such as a
petrol station, chemical depot, etc.
• Only operate this device within the temperature range of 0
°
C - 45
°
C
(32
°
F - 113
°
F).
• Do not expose this device to temperatures above 60
°
C (140
°
F).
• Do not use this device if it is visibly damaged.
• Do not disassemble, incinerate, or crush this device.
• Keep this device out of reach of children and pets.
`^rqflkW
Users of this device are cautioned to only use accessories and peripher-
als approved by Equinox Payments. Changes to this device or use of
accessories other than recommended or approved by Equinox Payments
may result in the loss of the user’s authority to operate the device.
Powered Supply Adapter
Right Angle
(P/N 810411-001)
USB Cable
(P/N 810371-012)