4

Check the plug and cable before connecting the power and 
ensure it is 110 voltage.

Rotate the Fan Speed Knob from the 0 (Off) position to either 
low or high cool setting.

The Cooling Air Hose can be rotated 360 degrees, allowing for 
maximum flexibility in positioning the flow and direction of cool air.

Press the Power Button to turn the OAC on.

After turning off the OAC, wait 5 minutes before turning it on 
again. It cannot be turned on immediately.

The OAC is equipped with overheat and overload protection for 
the compressor. If the compressor overheats because of voltage 
fluctuations or high ambient temperature, the compressor power 
supply shuts off and the OAC will blow only ambient air.

Power Button

Fan Speed Knob

Operation

In the course of operating the OAC, condensate water is 
produced. The water can either be collected in the Water Tank 
or can be discharged directly outdoors through a Drainage Hose
included with the unit.

Water Tank and Drainage Hose

Water Tank

The Water Tank is located at the bottom of the OAC. It is
important to empty the tank in a timely manner. Check the
water level every 2-3 days.

Turn the power off before emptying the Water Tank. 

Summary of Contents for OAC 2000

Page 1: ...Read the instructions carefully and keep for future reference OWNER S MANUAL Model OAC 2000 OUTDOOR AIR CONDITIONER ...

Page 2: ......

Page 3: ... warranty does not cover service calls which do not involve defective workmanship or materials covered by this warranty Accordingly diagnosis and repair costs for a service call which does not involve defective workmanship or materials will be the responsibility of the consumer owner Warranty Exclusions Specifically the following work is not covered under warranty and does not constitute warranty w...

Page 4: ... For Customer Service This warranty is given by Equator Appliances 10216 Georgibelle Drive Suite 900D Houston TX 77043 5249 Since it is a responsibility of the consumer owner to establish the warranty period by verifying the original purchase date Equator Appliances recommends that a receipt delivery slip or some other appropriate payment record be kept for that purpose This warranty gives you spe...

Page 5: ...ord Do not use an extension cord Do not operate the unit with wet hands to prevent electric shock Children should be supervised to ensure that they do not climb on or play with the appliance This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruct...

Page 6: ...Cooling Air Hose The Cooling Air Hose is flexible can be rotated 360 degrees and can be positioned to blow to a desired area The Control Panel at the top of the OAC is used to select low or high fan speed to regulate the cool air flow Description Hot air is exhausted through the back of the unit Condensate is collected in a Water Tank below the unit or can be discharged directly to a designated area...

Page 7: ...for outdoor use and is portable The compact size and casters enable it to be moved easily Place the appliance away from sources of heat and high humidity Place the OAC in a covered area to protect from direct sunlight and heavy rainfall for greater longevity Ensure there is adequate ventilation around the OAC The Air Intake Screen and Cooling Air Hose should be more than 1 foot 30 cm away from wal...

Page 8: ... and overload protection for the compressor If the compressor overheats because of voltage fluctuations or high ambient temperature the compressor power supply shuts off and the OAC will blow only ambient air Power Button Fan Speed Knob Operation In the course of operating the OAC condensate water is produced The water can either be collected in the Water Tank or can be discharged directly outdoors ...

Page 9: ...r the OAC and store in an upright position Remove the Water Tank discard the water and then replace it again before turning the OAC on Do not move the OAC when it is full of water Drainage Hose Remove the Water Tank Attach the Drainage Hose directly onto the outlet where it enters the Water Tank cavity The Hose can be held in place with the Hose Clip provided Before storing for an extended time 5 ...

Page 10: ...heck for proper ventilation and that air inlet or outlet is not blocked Not Cooling Water Leak Drain is blocked Needs to be cleared Water Tank is full and needs to be emptied Possible Cause and Solution Problem Move it if near a heat source or in direct sunlight Voltage is not correct Compressor overheating Shut down and restart after some time Water Tank is not placed correctly Ambient temperatur...

Page 11: ...ower Refrigerant Working Temperature Weight Net Gross Product Dimensions HxWxD Packaging Dimensions HxWxD OAC 2000 2000W 6800BTU 110V 60Hz 6 4 Amps 700 W R410A 64 4 F 113 F 56 2 66 lbs 22 4 x 18 9 x 11 inch 25 x 22 x 15 inch O O Air Flow 135 4 cu ft min Electrical Diagram ...

Page 12: ......

Reviews: