OPERATOR INSTRUCTION MANUAL
IM_FA1TM_Rev08_A4
FA1TM
FLANGE ALIGNMENT TOOL
6
ACTUATING THE FA1TM
Carry out the Flange Misalignment Determination
Procedure (see Section 3) to determine the points of
maximum misalignment.
In this example the points of maximum misalignment
are the top and bottom of the joint.
POINT OF MAX.
MISALIGNMENT
POINT OF MAX.
MISALIGNMENT
Guide the lift hook into the bolt-hole at the point of
maximum misalignment.
Adjust the drop leg down onto the pipe by slackening
the release knob in an anticlockwise direction.
The tool should be held up level within the bolt-hole
during adjustment. NB: The tool must be parallel to
pipe during operation.
DROP LEG
RELEASE
KNOB
LIFT HOOK
PARALLEL
The drop leg release knob is then tightened until
firm.
Rotate the crank handle clockwise until the driven
wedge makes contact with the opposite flange.
CRANK
HANDLE
DRIVEN
WEDGE
OPPOSITE FLANGE
Thread the strap through the aperture on the base
of the drop leg as shown.
STRAP
STRAP
APERTURE
Feed the open end of the strap through the buckle
mechanism as shown.
Close the clasp to secure strap.
FEED THROUGH
STRAP
Summary of Contents for FA1TM