background image

O P E R ATO R   I N S T R U C T I O N   M A N U A L

E Q U A L I Z E R   I N T E R N A T I O N A L   L T D

w w w. e q u a l i z e r i n t e r n a t i o n a l . c o m

F L A N G E

A L I G N M E N T

T O O L

FA1TM

Summary of Contents for FA1TM

Page 1: ...OPERATOR INSTRUCTION MANUAL E Q U A L I Z E R I N T E R N AT I O N A L LT D w w w e q u a l i z e r i n t e r n a t i o n a l c o m F L A N G E A L I G N M E N T T O O L FA1TM ...

Page 2: ...ATERAL MISALIGNMENT 4 FA1TM MECHANICAL FLANGE ALIGNMENT TOOL 4 1 TOOL CAPABILITIES 4 2 RANGE OF APPLICATION 4 3 TOOL FUNCTION 4 4 KIT CONTENTS 4 5 TOOL DIMENSIONS 4 6 TOOL MAINTENANCE 5 RANGE OF APPLICATION 5 1 BS10 API6BX API6B WELD NECK FLANGE TABLES 5 2 ASME B16 5 ASME B16 47 DIN WELD NECK FLANGE TABLES 5 3 SPO FLANGE TABLE 6 TROUBLESHOOTING 6 1 FA1TM TROUBLESHOOTING 7 REGULATORY INFORMATION 7 ...

Page 3: ...ols The use of these tools should be as part of a broader task based risk assessment which should be carried out by the operation supervisor or other competent person Failure to comply with the safety information contained within this manual could result in personal injury or equipment damage Read all instructions warnings and cautions carefully and follow all safety precautions The safety of the ...

Page 4: ...re Protect hoses from dropped objects a sharp impact may cause internal damage to hose wire strands Protect hoses from crush risks such as heavy objects or vehicles crush damage can cause hose failure WARNING Applying pressure to a damaged hose may cause it to rupture WARNING Immediately replace worn or damaged parts Use only genuine Equalizer parts from approved distributors or service centres Eq...

Page 5: ...ery second bolt around the flange Continue with this until misalignment occurs A flanged joint once broken down may spring out of alignment at any point or in any direction around its circumference Misalignment may not occur until only a few bolts remain 2 At this point the direction of any misalignment should become obvious The alignment tool being used should be attached at the maximum point of ...

Page 6: ...DIMENSION B 4 3 FA1TM TOOL FUNCTION FA1TM GENERAL GUIDANCE 1 The FA1TM is secured to the lower of the two flanges by fully inserting the lift hool into the bolt hole at the point of greatest misalignment 2 The drop leg release knob is slackened and the drop leg is adjusted down to the pipe while the tool is held level in the bolt hole 3 The drop leg release knob is then tightened until firm 4 The ...

Page 7: ...own onto the pipe by slackening the release knob in an anticlockwise direction The tool should be held up level within the bolt hole during adjustment NB The tool must be parallel to pipe during operation DROP LEG RELEASE KNOB LIFT HOOK PARALLEL The drop leg release knob is then tightened until firm Rotate the crank handle clockwise until the driven wedge makes contact with the opposite flange CRA...

Page 8: ...o the circumference of the opposite flange bring the flange joint in alignment WARNING Do not exceed hand pressure on the crank handle Once in alignment the bolts may be inserted and tightened After replacing all of the bolts apart from the bolt which will go into the bolt hole in which the FA1TM is located remove the tool by reversing the previous steps Insert the last bolt and tighten WARNING Ca...

Page 9: ...e strip the tool down observing the schematics in section 8 clean the components using detergent following the manufacturer s guidelines rinse the components to remove traces of detergent dry the component thoroughly Inspect service and lubricate the tool immediately after the cleaning process SERVICING Replace missing worn or damaged parts Use only genuine Equalizer parts from approved distributo...

Page 10: ...where not vacuum sealed as much air from bags as possible 6 Once bags have been closed and sealed DO NOT re open Any visual inspections must be done with closed and sealed bags If bags are opened the components will have to be dried re coated and re sealed in bags shrink wrap 7 Replace silica gel 100g EVERY TIME the case is opened NOTE depending on moisture content of air silica gel should be chan...

Page 11: ... 10 12 13 14 15 16 17 18 19 20 TOOL FA1TM FA4TM FA9TE CLASS R NPS 1 1 1 4 1 1 2 2 2 1 2 3 3 1 2 4 5 6 7 8 9 10 12 13 14 15 16 17 18 19 20 TOOL FA1TM FA4TM FA9TE CLASS S NPS 1 2 3 4 1 1 1 4 1 1 2 2 2 1 2 3 3 1 2 4 4 1 2 5 6 7 8 9 10 11 12 13 14 15 16 SUITABLE FOR FA1TM TOOL TOOL FA1TM FA4TM FA9TE SUITABLE FOR FA4TM TOOL CLASS T NPS 1 2 3 4 1 1 1 4 1 1 2 2 2 1 2 3 3 1 2 4 4 1 2 5 6 7 8 9 10 11 12 13...

Page 12: ...E OF APPLICATION CLASS 150 NPS 22 26 28 30 32 34 36 38 40 42 44 46 48 TOOL FA4TM FA9TE CLASS 300 NPS 22 26 28 30 32 34 36 38 40 42 44 46 48 TOOL FA4TM FA9TE CLASS 400 NPS 22 26 28 30 32 34 36 38 40 42 44 46 48 TOOL FA4TM FA9TE CLASS 600 NPS 22 26 28 30 32 34 36 38 40 42 44 46 48 TOOL FA4TM FA9TE CLASS 900 NPS 22 26 28 30 32 34 36 38 40 42 44 46 48 TOOL FA9TE DIN WELD NECK FLANGE RANGE OF APPLICATI...

Page 13: ... 4 5 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 TOOL FA4TM FA9TE CLASS 1500 NPS 2 1 2 3 3 1 2 4 5 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 TOOL FA4TM FA9TE CLASS 2500 NPS 2 1 2 3 3 1 2 4 5 6 8 10 12 14 16 18 20 22 24 TOOL FA4TM FA9TE CLASS 5000 NPS 2 1 2 3 3 1 2 4 5 6 8 10 12 14 16 18 20 22 24 TOOL FA4TM FA9TE CLASS 7500 NPS 2 1 2 3 3 1 2 4 5 6 8 10 12 1...

Page 14: ... S E There may be something restricting the joint from aligning R E C O M M E N D E D A C T I O N Check the area around the joint to establish if there is an obstruction to the joint P O S S I B L E C A U S E The joint may require more than 1 T 10 kN force to align R E C O M M E N D E D A C T I O N If the joint requires more force than that of the 1 T 10 kN tool attach a second tool or another met...

Page 15: ... MANUAL IM_FA1TM_Rev08_A4 FA1TM FLANGE ALIGNMENT TOOL 14 7 REGULATORY INFORMATION 7 1 REGISTERED HEAD OFFICE EQUALIZER INTERNATIONAL LTD Equalizer House Claymore Drive Aberdeen Scotland AB23 8GD 8 PARTS LISTS SERVICE KITS ...

Page 16: ...10100 01 211600 01 220800 01 BODY FRAME DRIVEN WEDGE DRIVE SCREW BASE PLATE 3 mm COVER PLATE 2 mm CRANK HANDLE TORSION SPRING NEEDLE BEARING BEARING SHAFT SPRING MANDREL M6 x 8 mm SOCKET FL BT SCREW DROP LEG M6 RELEASE KNOB LEG PIN 8 mm SPRING RING 8 mm SPRING PIN 2 x 16 mm BODY STICKER LEFT BODY STICKER RIGHT DRIVING WEDGE SPACER SHIM MINI RATCHET STRAP 01 01 01 01 01 01 01 04 04 01 12 01 01 01 0...