System Settings
Default Settings
See the sections below for details on each of the Skyjack SJIII OverWatch™ system default settings.
Setting Name
Description
Default
deltaseek
This specifies which of the previous lidar reading to
compare against the current one to calculate the speed.
20
max_safe_velocity
This is the velocity threshold for the cutout in cm/s. for
drive mode.
90
max_safe_displacement
This is the maximum permitted distance in cm the operator
may be away from the calibration position in drive mode.
40
max_safe_velocity_elevate
This is the velocity threshold for the cutout in cm/s. in
elevate mode.
70
max_safe_displacement_elevate
This is the maximum permitted distance in cm the operator
may be away from the calibration position in elevate mode.
40
max_safe_velocity_neutral
This is the velocity threshold for the cutout in cm/s. in
neutral mode.
60
max_safe_displacement_neutral
This is the maximum permitted distance in cm the operator
may be away from the calibration position in neutral mode.
40
fwddispadj
The coefficient to apply to the displacement when the
displacement is toward the sensor.
-0.6
fwdveladj
The coefficient to apply to the velocity when the
displacement is toward the sensor.
-1.0
zone_obstruction
If the lidar sensor reading is below this, the lidar is
considered to be obstructed (with paint or thick coat of
dust) and the system is cutout until the obstruction is
cleared.
5
zone_minimum
Any lidar reading below this will trigger a cutout with the
message: “Operator Zone”
15
zone_maximum
Any lidar reading above this will trigger a cutout with the
message: “Operator Zone”
120
horn_count_max
The number of times the horn will sound when alerting the
operator if the deadman remains pressed during the
cutout.
2
horn_time_ms
The amount of time in milliseconds each individual horn
should play.
200
adc_elevate_threshold
For the elevate ADC input, a reading above this indicates
the EWP is in elevate mode.
2200
adc_drive_threshold
For the drive ADC input, a reading above this indicates the
EWP is in drive mode.
2200