Deleting MIN-/MAX values
All stored MIN-/MAX values of all sensors will be deleted to-
gether!
- Press the key ”MIN MAX” long.
- The hole display disappears, after this ”rEs” appears for approx.
2 seconds.
- After this the display goes to the normal mode before clearance.
The current values are immediately taken over as the new MIN-/MAX
values.
9.4. Selecting temperature metered value (Temp./Dewpoint)
For the reading in display panel B you can switch between displaying
the temperature and the associated dewpoint.
Change between temperature and dewpoint
- Press the key ”SELECT” shortly. Temperature value in display panel
B changes between temperature and dewpoint. At dewpoint choice
accessorily ”Dewpoint” appears in the display.
9.5. Frost warning
The frost warning is always active. This function warns, if the temperature
of the sensor, which is displayed in the particular display panel, is below
39.2˚F.
First time after temperature is below 39.2˚F, the frost warning symbol
in the according display panel is blinking for 30 seconds, after this the
frost warning symbol remains on permanently.
F
•
While retrieving the MIN-/MAX values for display panel A, also
the display panel B respectively changes between MIN- and
MAX value, but only the MIN-/MAX values since last clearance
(reset) are displayed!
•
After choosing a storage display (MIN-/MAX value), you can
successive call the particular extreme value of all sensors into
display panel B by pressing the key ”SENSOR” frequently
short.
•
The device goes back to the display of current value after ”MAX
value last month” in display panel A.
F