17. Switching nominal/actual temperature (S-A)
In the factory settings, the display will show the nominal
temperature. In the configuration menu, you can change
the display setting from nominal to acutal temperature.
•
Open the configuration menu by pressing the
menu button.
•
Select the (
S-A
) menu item with the (
+
) and (
-
) but-
tons and confirm with the OK button.
•
Now set the format you want to show on the display
(„
SEt
“ for the nominal temperature and „
ACt
“ for
the actual temperature) with the (
+
) and (
-
) buttons.
• Confirm setting with the OK button.
If the actual temperature is selected,
the display will disbplay „SEt“ for 5
seconds on change of the nominal
temperature (or on change of mode).
Afterwards, the display automatically
changes back to actual temperature.
18. Comfort and reduced temperature ( )
The comfort ( ) and reduced ( ) temperature buttons
make switching between comfort and reduced temperature
simple and user friendly. The factory setting for the comfort
temperature is 21.0°C and the reduced temperature 17.0°C.
These can be changed permanently as follows:
•
Press the comfort ( ) / reduced ( ) temperature
button for a few seconds.
•
The display shows the respective symbol and the
corresponding comfort or reduced temperature.
•
Change the temperature with the (
+
) and (
-