The  management software provides a user-friendly 
interface for your power systems. The graphic interface 
is intuitive and displays essential power informations. 

Installation procedure: 

 

1. Download Power Guide software (for Windows or 

Linux) or Power Master software (for MacOS) from 
the website: www.justepyc.com 

2. Double-click the file and follow the installation steps. 
3. Power Guide: when your computer restarts, the 

Power Guide software will appear as a blue icon 
located in the system tray. 
Power Master: to access Power Master enter http://localhost:3052 address on your web browser. 

 
 

 

 

Before starting any cleaning operation, be sure that

:  

1. The AC Input Voltage for the UPS has been removed.  
2. The UPS is OFF.  
Use a cloth moisteened only with water to externally clean the UPS. Before restarting the UPS be sure it is completely 

dry. 
If the UPS works in an environmental unusually dusty or dirty, remove the dirty from the ventilation holes 
If any liquid gets inside the UPS, do not start the unit and contact Technical Service immediately. 

UPS status 

LED status 

Alarm 

Normal 

LED lighting 

Off 

Battery discharge 

LED lighting 

Beep once every 30 seconds 

Battery low 

LED lighting 

Beep once every 2 seconds 

Overload 

LED lighting 

Beep once every 0,5 seconds 

Off Charging mode 

LED off 

Off 

Fault 

LED off 

Continuous alarm 

Model 

1500VA 

2200VA 

Capacity  (VA/W) 

1500/900 

2200/1320 

Input

 

Nominal Voltage range 

162-290VAC

 

NominalFrequency range 

50/60Hz

 

Output

 

On Battery Output Voltage 

220-240VAC

 

On Battery Output Frequency 

50/60Hz+/-1%

 

Overload Protection 

Breaker

 

Physical

 

Dimensions WxHxD (mm) 

148x178x298 

Weight 

9.1 kg 

10.0 kg 

Battery

 

Sealed Maintenance Free 

Lead Acid Battery 

2x 12V/7.5Ah 

2x 12V/9Ah 

Typical Recharge Time 

8 Hours

 

Warning Diagnostics

 

Indicators 

Power On

 

Audible Alarms 

On Battery, Low Battery, Overload, Fault

 

Environmental

 

Operating Temperature 

0°C to 40°C

 

Operating Relative Humidity 

0 to 90%

 

Management

 

Auto-Charger 

Yes 

Auto-Restart 

Yes 

USB COMM.Port 

Yes 

RJ45/11Communication 

Protection Ports 

No 

Problem 

Possible Cause 

Solution 

The UPS does not perform 

expected runtime. 

Batteries are not fully charged. 

Recharge the battery by leaving the UPS plugged in. 

Battery is slightly worn out. 

Contact Technical Support for battery replacing. 

The UPS will not turn on. 

The unit is not connected to an AC 

outlet. 

The unit must be connected to a 220-240V outlet.

 

The battery is worn out. 

Contact Technical Support for battery replacing. 

Mechanical problem. 

Contact Technical Support. 

Outlets do not provide 

power to equipment 

Circuit breaker is tripped 

due to overload. 

Turn the UPS off and unplug at least one piece connected 

equipment. Unplug the power cord of the UPS then press 

the circuit breaker knob. 

Batteries are discharged 

Allow the unit to recharge for at least 4 hours. 

UPS has been damaged by a 

surge or spike. 

Contact Technical Support. 

Fault code F09 

Output short: 

output circuit short. 

Shutdown the UPS. Your attached equipment may have problems, 

please remove them and check again. 

Fault code F12 

Battery voltage is too low. 

Shutdown your computer and recharge the battery immediately. 

Fault code F13 

Battery is overcharged. 

Contact Technical Support.

 

Fault code F14 

Overload occurs: 

your equipment requires more 

power than the UPS can provide. 

It twill shutdown. 

Shut off non-essential equipment. 

If this solves the overload problem, the UPS will transfer 

to normal operation.

 

TECHNICAL SPECIFICATIONS 

LED INDICATION AND ALARM 

MANAGEMENT SOFTWARE DOWNLOAD 

MAINTENANCE 

TROUBLE SHOOTING 