The management software provides a user-friendly
interface for your power systems. The graphic interface
is intuitive and displays essential power informations.
Installation procedure:
1. Download Power Guide software (for Windows or
Linux) or Power Master software (for MacOS) from
the website: www.justepyc.com
2. Double-click the file and follow the installation steps.
3. Power Guide: when your computer restarts, the
Power Guide software will appear as a blue icon
located in the system tray.
Power Master: to access Power Master enter http://localhost:3052 address on your web browser.
Before starting any cleaning operation, be sure that
:
1. The AC Input Voltage for the UPS has been removed.
2. The UPS is OFF.
Use a cloth moisteened only with water to externally clean the UPS. Before restarting the UPS be sure it is completely
dry.
If the UPS works in an environmental unusually dusty or dirty, remove the dirty from the ventilation holes
If any liquid gets inside the UPS, do not start the unit and contact Technical Service immediately.
UPS status
LED status
Alarm
Normal
LED lighting
Off
Battery discharge
LED lighting
Beep once every 30 seconds
Battery low
LED lighting
Beep once every 2 seconds
Overload
LED lighting
Beep once every 0,5 seconds
Off Charging mode
LED off
Off
Fault
LED off
Continuous alarm
Model
1500VA
2200VA
Capacity (VA/W)
1500/900
2200/1320
Input
Nominal Voltage range
162-290VAC
NominalFrequency range
50/60Hz
Output
On Battery Output Voltage
220-240VAC
On Battery Output Frequency
50/60Hz+/-1%
Overload Protection
Breaker
Physical
Dimensions WxHxD (mm)
148x178x298
Weight
9.1 kg
10.0 kg
Battery
Sealed Maintenance Free
Lead Acid Battery
2x 12V/7.5Ah
2x 12V/9Ah
Typical Recharge Time
8 Hours
Warning Diagnostics
Indicators
Power On
Audible Alarms
On Battery, Low Battery, Overload, Fault
Environmental
Operating Temperature
0°C to 40°C
Operating Relative Humidity
0 to 90%
Management
Auto-Charger
Yes
Auto-Restart
Yes
USB COMM.Port
Yes
RJ45/11Communication
Protection Ports
No
Problem
Possible Cause
Solution
The UPS does not perform
expected runtime.
Batteries are not fully charged.
Recharge the battery by leaving the UPS plugged in.
Battery is slightly worn out.
Contact Technical Support for battery replacing.
The UPS will not turn on.
The unit is not connected to an AC
outlet.
The unit must be connected to a 220-240V outlet.
The battery is worn out.
Contact Technical Support for battery replacing.
Mechanical problem.
Contact Technical Support.
Outlets do not provide
power to equipment
Circuit breaker is tripped
due to overload.
Turn the UPS off and unplug at least one piece connected
equipment. Unplug the power cord of the UPS then press
the circuit breaker knob.
Batteries are discharged
Allow the unit to recharge for at least 4 hours.
UPS has been damaged by a
surge or spike.
Contact Technical Support.
Fault code F09
Output short:
output circuit short.
Shutdown the UPS. Your attached equipment may have problems,
please remove them and check again.
Fault code F12
Battery voltage is too low.
Shutdown your computer and recharge the battery immediately.
Fault code F13
Battery is overcharged.
Contact Technical Support.
Fault code F14
Overload occurs:
your equipment requires more
power than the UPS can provide.
It twill shutdown.
Shut off non-essential equipment.
If this solves the overload problem, the UPS will transfer
to normal operation.
TECHNICAL SPECIFICATIONS
LED INDICATION AND ALARM
MANAGEMENT SOFTWARE DOWNLOAD
MAINTENANCE
TROUBLE SHOOTING