SERVICE MANUAL TANGO KW (short version) ENGLISH
Autori: Serralunga M.
16/07/2020
27
NO COPYING IN ANY FORM WITHOUT WRITTEN PERMISSION FROM EPTA QUALITY MANAGEMENT
5.11
REPLACEMENT OF CONDENSER MOTOR FAN
Disconnect the motor fan by disconnecting the terminal junction shown In figure, releasing
wires from cable ties. Remove the hexagonal-head screw, marked in figure; extract the motor
fan from compressor compartment; unscrew the hexagonal-head screw fixing the motor fan
blade and remove the screws fastening the motor to its metal support.
5.12
REPLACEMENT OF EVAPORATOR MOTOR FAN
1 – Unscrew and remove evaporator cover.
2 – Disconnect the motor fan connectors.
3 – Unscrew and remove the motor fan.
Epta code:
I0220093
Model:
ECM 12-15 115/50-60
Epta code:
I0407016
Model:
PLASTIC FAN BLADE AP 200-28
Epta code:
42687032
Model:
MV 115V 50/60HZ 14W
ELCO ECM HBS 12-10-1