Adjustment
Details of Adjustments
67
Epson WF-7620 / WF-7610 / WF-7110 Series
Revision B
APG Position Check
Make sure the APG position is in the [PG1] position.
How to check
If it is in the [PG1] position, the lever of the APG transmission slider on the rear of the CR Unit cannot be seen.
(See
Figure 3-6. APG Position Check
If the lever is in the NG condition shown in
, set it in the [PG1] position as follows.
1.
Move the Carriage Assy to the center of the printer.
2.
Rotate the gear on the APG Unit shown in
in the direction of the arrow until the APG Lever comes
out from the hole on the Main Frame.
3.
Move the CR Unit to the 130-digit side until it touches the APG Lever.
4.
Check the APG transmission slider is in the “OK” status shown in
Figure 3-7. APG Lever
Confirmation of the PG adjustment cam positions
Make sure the center of the notches on the PG adjustment cam on both sides of the printer is set to the rib of
the frame.
Figure 3-8. PG Adjustment Cams
Lever of APG transmission slider
NG
CR Unit
Rear of CR Unit
CR Unit
Rear of CR Unit
OK
APG Lever
OK
NG
Gear of APG unit
CR Guide Frame
Rib
To -
PG: Max.
To +
PG: Min.
Rib
To +
PG: Min.
To -
PG: Max.
PG adj. cam L (130-digit side)
PG adj. cam R (0-digit side)
Summary of Contents for WF-7110 Series
Page 8: ...5 2 Protection for Transportation 86 5 2 1 Securing the CR Unit 86 ...
Page 9: ...Confidential CHAPTER 1 TROUBLESHOOTING ...
Page 23: ...Confidential CHAPTER 2 DISASSEMBLY REASSEMBLY ...
Page 52: ...Confidential CHAPTER 3 ADJUSTMENT ...
Page 75: ...Confidential CHAPTER 4 MAINTENANCE ...