Confidential
EPSON
TITLE
SHEET
REVISION
NO.
SHEET
NEXT
TM-U220A
Specification
(For Argentina Fiscal)
62
63
A
<Function 1>
GS ( C
p
L
p
H
m fn b c1 c2 d1...dk
(
fn
= 1, 49)
[Format] ASCII GS
( C
p
L
p
H
m fn b c1 c2 d1...dk
Hex 1D
28
43
p
L
p
H
m fn b c1 c2 d1...dk
Decimal 29 40 67
p
L
p
H
m fn b c1 c2 d1...dk
[Range] 6
≤
(
p
L
+
p
H
×
256)
≤
65535 (0
≤
p
L
≤
255, 0
≤
p
H
≤
255)
m
= 0
fn
= 1, 49
b
= 0
32
≤
c1
≤
126
32
≤
c2
≤
126
32
≤
d
≤
254
k
= (
p
L
+
p
H
×
256) - 5
The entire capacity size = 8 KB.
[Description]
•
Stores the data (
d1...dk
) as the record specified by the key codes (
c1, c2
) in the NV
user memory.
•
[d1...dk]
specify the stored data (contents of the record).
[Note]
•
If the number of data ((
pL
+
pH
×
256) – 5) exceeds the remaining capacity of the NV
user memory, this function does not work.
<Function 2>
GS ( C
pL pH m fn b c1 c2
(
fn
= 2, 50)
[Format] ASCII GS
( C
p
L
p
H
m fn b c1 c2
Hex 1D
28
43
p
L
p
H
m fn b c1 c2
Decimal 29 40 67
p
L
p
H
m fn b c1 c2
[Range] (
p
L
+
p
H
×
256) = 5 (
p
L
= 5,
p
H
= 0)
m
= 0
fn
= 2, 50
b
= 0
32
≤
c1
≤
126
32
≤
c2
≤
126
[Description]
•
Transmits data for the record specified by the key codes (
c1, c2
) in the NV user
memory.
<Function 3>
GS ( C
p
L
p
H
m fn b
(
fn
= 3, 51)
[Format] ASCII GS
( C
p
L
p
H
m fn b
Hex 1D
28
43
p
L
p
H
m fn b
Decimal 29 40 67
p
L
p
H
m fn b
[Range] (
p
L
+
p
H
×
256) = 3 (
p
L
= 3,
p
H
= 0)
m
= 0
fn
= 3, 51
b
= 0
[Description]
•
Transmits the number of bytes of the memory used in the NV user memory.