EPSON Stylus Pro 4400/4450/4800/4880/4880C
Revision C
Disassembly & Assembly
Disassembly Procedures
357
4.2.9.9 PF Encoder Sensor
1.
2.
Remove the two screws securing the "PF Encoder Sensor".
C.P.P. 2.6x8:
2 pcs.
3.
Disconnect the connector from the "PF Encoder Sensor" and then remove
the "PF Encoder Sensor".
Figure 4-222. PF Encoder Sensor Removal
C A U T I O N
Be careful not to deform or damage the "Scale, PF" attached
to the "Pulley, Roller, PF".
Align the two dowels of the "PF Encoder Sensor" with
the two positioning holes on the "Holder,Sensor.
Do not bend condenser.
After installing the "PF Encoder Sensor", confirm that
the "PF Scale" is surely inserted into the sensor slit.
Confirm that the "PF Scale" is not contacting the sensor.
Dowels
Positioning Holes
A D J U S T M E N T
R E Q U I R E D
Be sure to refer to Chapter 5
and
perform specified adjustments after replacing the "PF
Encorder Sensor".
PF Scale
PF Encoder Sensor
Connector
Condenser
C.P.P. 2.6x8