SC-F7000 Serie/SC-B7000 Series
Revision A
DISASSEMBLY & ASSEMBLY
Disassembly and Assembly Procedure
71
Confidential
3.4.5.14 Pump Cap Unit
1. Unlock the CR Unit.
2. Remove the Media Loading Lever.
3. Remove the Panel Unit.
4. Remove the Right Upper Cover.
5. Remove the Right Cover.
6. Move the CR Unit to a position over the platen.
7. Remove the screw, and remove the cable cover.
A) Silver M4x8 S-tite screw with built-in washer: 1 pcs
Figure 3-27. Removing the Cable Cover
8. Open the clamp.
9. Disconnect the cable from the three relay connectors (No.36, No.37, and No.79).
aa
Figure 3-28. Disconnecting from the Relay Connectors
A D J U S T M E N T
R E Q U I R E D
When replacing/removing this part, refer to
Items and the Order by Repaired Part” (p86)
and make sure to
perform the specified operations including required adjustment.
When installing the cable cover, be careful not to let the cable get
caught between the cover and frame.
A
Cable Cover
Clamp
No.36
No.37
No.79
Summary of Contents for SC-B7000 Series
Page 6: ...Confidential Revision Status Revision Date of Issue Description A March 14 2013 First release ...
Page 9: ...Confidential C H A P T E R 1 PRODUCTDESCRIPTION ...
Page 30: ...Confidential C H A P T E R 2 TROUBLESHOOTING ...
Page 42: ...Confidential C H A P T E R 3 DISASSEMBLY ASSEMBLY ...
Page 84: ...Confidential C H A P T E R 4 ADJUSTMENT ...
Page 123: ...Confidential C H A P T E R 5 MAINTENANCE ...