9
Switch measurement mode
You can switch to any measurement mode by setting the rotary switch. Check the
correspondence between the set value, measurement mode and jumper setting from
the table below.
Except for default range, please refer to the “S5U1C17M03T Manual”.
# SW1
Measurement
mode
Default range
Mode
name
JP2
JP3
JP4
JP5
JP6
JP8
JP9
0
DC voltage
6V
DCV
open
short
short
open
open
open
open
1
AC voltage
6V
ACV
open
short
short
open
open
open
open
2
DC current
6mA
DCI
open
short
short
2-3short
short
short
open
3
AC current
6mA
ACI
open
short
short
2-3short
short
short
open
4
Resistance
(CC-method)
600Ω
OHM CC
short
short
short
open
open
open
open
5
Resistance
(CV-method)
600Ω
OHM CV
short
short
short
open
open
open
open
6
Continuity check
CV
CONT
short
short
short
open
open
open
open
7
Capacitance
(CC-method)
1uF
CAP CC
short
short
short
open
open
open
open
8
Capacitance
(CV-method)
10nF
CAP CV
short
short
short
open
open
open
open
9
Diode VF
-
DIODE
short
short
short
open
open
open
open
A
AC voltage and
frequency
6V
FREQ ACV
open
short
short
open
open
open
open
B
AC current and
frequency
6mA
FREQ ACI
open
short
short
2-3short
short
short
open
C
Internal
temperature
-
TEMP
open
short
short
open
open
open
open
COM
MEAS
T13
T12
uA/mA
A
T16
T15
・
Connection of the positive probe
Current measurement(A range)
:
T15
Current measurement(uA/mA range) :
T16
Others
:
T12
・
Rotary switch