![Epson RX8804CE Applications Manual Download Page 13](http://html.mh-extra.com/html/epson/rx8804ce/rx8804ce_applications-manual_106864013.webp)
RX8804CE
Page - 8
ETM59E-05
8.1.3. Register Table (Time stamp, EVIN, SOUT, Timer)
Table 10 Register Table (10h ~ 1Fh)
Address
Function
bit 7
bit 6
bit 5
bit 4
bit 3
bit 2
bit 1
bit 0
Init
Write
10
Time stamp SEC
40
20
10
8
4
2
1
00h
−
11
Time stamp MIN
40
20
10
8
4
2
1
00h
−
12
Time stamp HOUR
20
10
8
4
2
1
00h
−
13
Time stamp WEEK
6
5
4
3
2
1
0
00h
−
14
Time stamp DAY
20
10
8
4
2
1
00h
−
15
Time stamp MONTH
TSVLF
TSVDET
10
8
4
2
1
00h
−
16
Time stamp YEAR
80
40
20
10
8
4
2
1
00h
−
17
EVIN set
ECP
EHL
EPU
RCE
EIE
ET1
ET0
00h
18
EVIN det
EF
EVMON
00h
19
SOUT set1
SOE7
SOE6
SOE5 SOE4 SOE3 SOE2 SOE1 SOE0
00h
1A
SOUT set2
DCE
DC
SRV
FS2
FS1
FS0
00h
1B
Timer set
TSTP
TRES
00h
1C
Timer0
128
64
32
16
8
4
2
1
00h
−
1D
Timer1
32768
16384
8192
4096
2048
1024
512
256
00h
−
1E
Timer2
8388608
4194304
2097152 1048576 524288
262144
131072
65536
00h
−
1F
Timer counter 2
8388608
4194304
2097152 1048576 524288
262144
131072
65536
00h
Writing is avoided. Read value is 0, always.
•
It can read and write.
is available.
−
avoid.
“Init”
shows value of after power-on Reset. Unit is Hex.
8.1.4. Quick Reference
Table 11 Quick Reference
Update interrupt timing
Default
USEL = 0
Once per seconds
USEL = 1
Once per minutes
Output Frequency selection
FSEL1, FSEL0 = 00
32.768 kHz
FSEL1, FSEL0 = 01
1024 Hz
FSEL1, FSEL0 = 10
1 Hz
FSEL1, FSEL0 = 11
32.768 kHz
Timer source clock selection
TSEL1, TSEL0 = 00
4096 Hz
TSEL1, TSEL0 = 01
64 Hz
TSEL1, TSEL0 = 10
Every second update
TSEL1, TSEL0 = 11
Every minute update
Temperature compensation selection
CSEL1, CSEL0 = 00
0.5 s
CSEL1, CSEL0 = 01
2.0 s
CSEL1, CSEL0 = 10
10 s
CSEL1, CSEL0 = 11
30 s
8.1.5 Initial Value of Registers
Table 12 Registers Initial Value
Registers’ Initial value after power on reset
Initial Value
Register
1
TSEL1, VLF, VDET, CSEL0
0
TEST, WADA, USEL, TE, FSEL1, FSEL0, TSEL0, UF, TF, AF, EF, CSEL1, UIE, TIE, AIE, RESET,
TSVLF, TSVDET, ECP, EHL, EPU, RCE, EIE, ET1, ET0, EVMON, SOE0 ~ SOE7, DCE, DC, SRV,
FS0 ~ FS2, TRES, TSTP, All bits of address1Ch,1Dh,1Eh and 1Fh
All other register values are undefined, so be sure to perform a reset before using the module.