15 Battery backup switchover function
RX8130CE
Jump to
ETM50E-07
Seiko Epson Corporation
45
Figure 34 VDET3, VDET4 voltage detection timing) BFVSEL1, BFVSEL0 bit
15.6 Detection voltage setting
Table 38 VDET1,VDET2,VDET3,VDET4 setting
Item
Symbol
Detect voltage Typ.
setting
V
DET1
Reset /Reset-release voltage
+V
DET11
/ -V
DET11
2.8V / 2.75V
RSVSEL = 0 (default)
+V
DET12
/ -V
DET12
2.7V / 2.65V
RSVSEL = 1
V
DET2
Backup switchover/recover voltage
+V
DET2
/ -V
DET2
1.35V / 1.30V
V
DET3
Full charge detection voltage
+V
DET31
/ -V
DET31
3.02V / 2.97V
BFVSEL = 00b
default)
+V
DET30
/ -V
DET30
2.92V / 2.87V
BFVSEL = 01b
+V
DET32
/ -V
DET32
3.08V / 3.03V
BFVSEL = 10b
V
DET4
V
BAT
low-voltage detection voltage
-V
DET4
2.4V
4) The full-charge detection (V
DET3
) and low-V
BAT
detection (V
DET4
) control SW2.
Table 39 BFVSEL1, BFVSEL0
BFVSEL1
BFVSEL0
Description
0
0
3.02 V (default)
0
1
3.08 V
1
0
2.92 V
1
1
OFF (Charging without limit)