EPSON Stylus Photo R1800/R2400
Revision B
Troubleshooting
Overview
50
Table 3-12. Troubleshooting of Fatal Error
Occurrence
Timing
Phenomenon Detail
Faulty Part/
Part Name
Check Point
Remedy
At power-on
At power-on, the CR Motor
does not operate at all.
CR Motor
1. Check that the CR Motor connector cable is connected to
the Relay Connector.
1. Connect the CR Motor connector to the
Relay Connector.
2. Check the CR Motor connector cable for damages.
2. Replace the CR Motor with a new one.
3. Check if the CR Motor operates normally.
3. Replace the CR Motor with a new one.
Relay
Connector
Cables
(for the CR
Motor)
1. Check that the Relay Connector Cable is connected to the
Main Board Connector CN15.
1. Connect the Relay Connector Cable to the
Main Board Connector CN15.
2. Check the Relay Connector Cable for damages.
2. Replace the Relay Connector Cable with a
new one.
CR Motor
Relay Connector
CN15
Summary of Contents for R1800 - Stylus Photo Color Inkjet Printer