PSB No: P-0071
Page: 3 of 7
TRANSMISSION VERIFICATION REPORT
1. To set the Transmission Verification Report to “ON”, enter the initial
maintenance mode.
Press the “START/COPY’ key 7 times and then
press the “FINE/PHOTO” key one time.
To set the Transmission Verification Report to “OFF”, enter the initial
maintenance mode. Press the “START/COPY’ key 8 times and then
press the “FINE/PHOTO” key one time.
2. Upon completion, the unit will print the change made and emit one
long beep indicating it has returned to the initial maintenance mode.
TEST PATTERN
1. To print the test pattern shown in Figure 1, enter the initial
maintenance mode. Press the “START/COPY’ key 9 times and then
press the “FINE/PHOTO” key one time.
2. Upon completion of the test pattern print out, the unit will emit one
long beep indicating it has returned to the initial maintenance mode.
SECOND LEVEL SOFT SWITCH FUNCTIONS
The second level of soft switch functions is accessed through switch 10 of
the initial level of function switches. Refer to Figure 2 for instructions on
accessing and changing these functions.
SECOND LEVEL SOFT SWITCH DATA PRINTOUT
1. To print the “System Configuration List” which contains the Second
Level Soft Switch Data, enter the initial maintenance mode. Press the
“PHOTO/FINE” key one time, press the “START/COPY” key one time
and then press the ‘PHOTO/FINE” key one time.
2. The unit will print the “System Configuration List” and emit one long
beep indicating it has returned to the initial maintenance mode.