EPSON Stylus CX1500/ME100
Revision A
DISASSEMBLY AND ASSEMBLY
Disassembly
90
4.3.9 ASF Unit
V
External View (1)
Figure 4-22. ASF Unit Removal (1)
V
Part/Unit that should be removed before removing ASF Unit.
Document Cover / Panel Unit / Panel Housing / Scanner Unit / Housing Upper /
Main Board Unit / Housing Middle
V
Removal procedure
1.
Remove the screws (x3,
) for securing ASF Unit, and then remove
ASF Unit from Printer Mechanism.
2.
Open Hopper, and then remove Compression Spring 2.50.
ASF Unit
1
3
2
Compression
Spring 2.50
Hopper Pad
Paper Return Plate Pad
C.B.S (P2) 3x6 F/Ni
(8±1kgfcm)
C.B.S 3x8 F/Ni
(6±1kgfcm)
C.B.S 3x6 F/Ni
(8±1kgfcm)
Shaft
C A U T I O N
Do not touch Hopper Pad and Paper Return Plate Pad.
T
Install ASF Unit while pressing by hand on Paper Return Plate.
T
Align the positioning hole (x1) of Main Frame with the dowel
(x1,
) of ASF Unit.
Figure 4-23. Installation of ASF Unit
T
Insert the shaft of ASF Unit into the slot of Ink System Unit.
T
Tighten the screws in the order as shown in the figure.
Dowel