ESC EM
Automatic Sheet Feeder Control
Format:
ASCII code:
ESC EM (n)
Decimal:
27 25
( n )
Hexadecimal:
1B 19 (n)
Control:
Ctrl[ Ctrl Y (n)
Explanation:
This command is used with the optional automatic-sheet
feeder. When n=
0
the feeder is turned off, when n = 4 it is
turned on. Using DIP Switch l-3 produces the same effect.
ESC <
Select Unidirectional Mode (one line)
Format:
ASCII code:
ESC <
Decimal:
27 60
Hexadecimal:
1B 3C
Explanation:
Selects unidirectional printing for more accurate positioning
during text printing for one line only, It is cancelled by a car-
riage return. (Graphics printing is always unidirectional.)
ESC U
Select Unidirectional Mode
Format:
ASCII code:
ESC U (n)
Decimal:
27 85 (n)
Hexadecimal:
1B 55
(n)
Explanation:
Selects unidirectional printing for more accurate positioning
during text printing. If n =
1
unidirectional mode is enabled,
while
n=O
disables the feature. (Graphics printing is always
unidirectional.)