Board Interfaces and Connectors
8
Seiko Epson Corporation
Epson IMU_OEM7 Interposer Board
User Manual (Rev. 1.3)
The following diagram shows the P2 connector wiring.
Figure 6-2 Epson G Series IMU Connector P2 Wiring
6.3. Epson V Series IMU Connector P3
The EIIB provides a 2x10 0.4 mm pitch socket connector P3 (Panasonic AXE120224) for directly
mounting the Epson V series IMU (M-V340). The P3 connector silk screen and mounting holes provides
a guide as to the correction mounting orientation of the Epson IMU.
NOTE:
Take precaution to ensure the supported Epson IMU is mounted correctly on P3, or else it may
cause permanent damage to the IMU, EIIB, or OEM7 Development Kit.
NOTE:
If using Epson V series IMU on P3, do not mount an Epson G series IMU on P2.
Table 6.3 Epson V Series IMU Connector P3
Pin Number
Signal Name
Description / Comment
1, 3, 5, 13, 20
GND
Circuit ground
2
SPI_MOSI
SPI Master Out Slave In (Supports SPI Mode 3 only)
4
SPI_CLK
SPI Clock (Supports SPI Mode 3 only)
5
SPI_MISO
SPI Master In Slave Out (Supports SPI Mode 3 only)
6
SPI_nCS
SPI Chip select (Supports SPI Mode 3 only)
10
IMU_UART_RXDI
For internal debug purpose only. Pulled to VCC with 10K ohm.
12
IMU_UART_TXDO
For internal debug purpose only
14
IMU_GPIO1_DRDY
IMU Data Ready Output
15, 17
3.3V
3.3V supplied by OEM7 Development Kit
16
GPIO2_EXT
IMU signal that can be optionally connected to:
-
OEM7 TIMEMARK (R1)
-
OEM7 EVENT_OUT2 (R2)
NOTE:
Do not mount both R1 and R2 at the same time.
Refer to Section
Error! Reference source not found.
Error! Re
ference source not found.
for more information.
18
IMU_nRESET
Connected to RC delay network
9, 11, 19
—
Not connected