139
List of ESC/VP21 Commands
Command List
When a power ON command is sent to the projector, the power for the
projector turns on. When the projector is in a command ready state, it
returns the "3Ah" (:) code.
Furthermore, when command processing is complete, the projector also
returns a ":" code.
The ":" code status can be used to determine whether the projector is ready
or busy. If command processing terminates with an error, an error message
is output and then the ":" code is sent.
Communication Protocol
Item
Command
Power ON/OFF
ON
PWR ON
OFF
PWR OFF
Signal selection
Computer
SOURCE 10
SOURCE 30
Video
SOURCE 41
S-Video
SOURCE 42
BNC
SOURCE B0
A/V Mute ON/OFF
ON
MUTE ON
OFF
MUTE OFF
A/V Mute Selection
Black
MSEL 00
Blue
MSEL 01
User's Logo
MSEL 02
•
Standard baud rate
: 9600 bps
•
Data length
: 8 bits
•
Parity
: None
•
Stop bit
: 1 bit
•
Flow control
: None
•
Connector shape
: D-Sub 9-pin (male)
•
Projector input port
: Control (RS-232C)