ISSUED: 02-13-08  SHEET #: 054-9126-2 07-10-08

Visit the Peerless Web Site at www.peerlessmounts.com

2 of 7

For Technical Support Contact Peerless Mounts at 1-800-729-0307 or 708-865-8870.

Table of Contents

Parts List .............................................................................................................................................................................. 3

Extension Column and Flush Mounting Applications ............................................................................................................ 4

Installation to Wood Joist Finished Ceilings, Exposed Wood Joists or Wood Beam Ceilings ............................................... 5

Installation to Solid Concrete ................................................................................................................................................ 6

Warranty Information ............................................................................................................................................................. 7

NOTE:

 Read entire instruction sheet before you start installation and assembly.

• Do not begin to install your product until you have read and understood the instructions and warnings contained in this

Installation Sheet. If you have any questions regarding any of the instructions or warnings, call Peerless customer care
at 1-800-729-0307.

• This product should only be installed by someone of good mechanical aptitude, has experience with basic building

construction, and fully understands these instructions.

• Make sure that the supporting surface will safely support the combined load of the equipment and all attached hard-

ware and components.

• Never exceed the Maximum UL Load Capacity.

• If mounting to wood joists or wood beam ceilings, make sure that mounting screws are anchored into the center of the

joists or beams. Use of an "edge to edge" stud finder is highly recommended.

• Always use an assistant or mechanical lifting equipment to safely lift and position equipment.

• Tighten screws firmly, but do not overtighten. Overtightening can damage the items, greatly reducing their holding

power.

• This product is intended for indoor use only. Use of this product outdoors could lead to product failure and personal

injury.

• When installing or adjusting the ceiling mount, do not  use adhesives, lubricants, or oils to prevent the screws from

loosening. If you use adhesives, lubricants, or oils to prevent the screws from loosening, the casing may crack and the
projector may fall, causing serious injury and damage to the projector.

WARNING

Tools Needed for Assembly

stud finder ("edge to edge" stud finder is recommended)

phillips screwdriver

3/8" (10 mm) socket wrench

drill

1/4" bit for concrete surface

5/32" bit for wood studs

Summary of Contents for ELPMBP03 - Structural Round Ceiling Plate

Page 1: ...65 2941 www peerlessmounts com Maximum UL Load Capacity 150 lb 68 kg This product is UL Listed It must be installed by a qualified professional installer R Installation and Assembly Structural Round Ceiling Plate Manufactured by Peerless Industries Inc ISSUED 02 13 08 SHEET 054 9126 2 07 10 08 ...

Page 2: ...ll safely support the combined load of the equipment and all attached hard ware and components Never exceed the Maximum UL Load Capacity If mounting to wood joists or wood beam ceilings make sure that mounting screws are anchored into the center of the joists or beams Use of an edge to edge stud finder is highly recommended Always use an assistant or mechanical lifting equipment to safely lift and...

Page 3: ...ppear slightly different than illustrated Before you begin make sure all parts shown are included with your product A B C D E F G Description Qty Part A round ceiling plate 1 055 2798 B 14 x 2 5 wood screw 4 5S1 015 C04 C M5 x 8 x 10 mm phillips screw 1 520 2005 D M5 x 8 x 10 mm socket pin screw 1 520 2031 E 4 mm allen wrench 1 560 9646 F rubber grommet 1 530 9401 G concrete anchor 4 590 0097 Part...

Page 4: ... grommet F into hole of ceiling plate A NOTE Make sure grommet overlaps retaining collar Grommet may require some force to fit in hole and will appear slightly deformed F A RETAINING COLLAR 1 Screw flush mount from top of ceiling plate A as shown in fig 2 Tighten four or five complete turns Align slot in flush mount tube with one of the small holes in the side of the threaded fitting Insert and ti...

Page 5: ...he equipment and all attached hardware and components Tighten wood screws so that ceiling plate is firmly attached but do not overtighten Overtightening can damage the screws greatly reducing their holding power Never tighten in excess of 80 in lb 9 N M Make sure that mounting screws are anchored into the center of the wood joist or wood beam The use of an edge to edge stud finder is highly recomm...

Page 6: ...al If mounting to concrete surfaces covered with a finishing surface is unavoidable the finishing surface must be counterbored as shown below Be sure concrete anchors do not pull away from concrete when tightening screws If plaster drywall is thicker than 5 8 custom fasteners must be supplied by installer Not evaluated by UL WARNING Tighten screws so that ceiling plate is firmly attached but do no...

Page 7: ...LV QRW DXWKRUL HG IRU VXFK VHUYLFH RU UHSDLUV E 3HHUOHVV QGXVWULHV QF E WKH IDLOXUH WR XWLOL H SURSHU SDFNLQJ ZKHQ UHWXUQLQJ WKH SURGXFW F LQFRUUHFW LQVWDOODWLRQ RU WKH IDLOXUH WR IROORZ 3HHUOHVVҋ LQVWUXFWLRQV RU ZDUQLQJV ZKHQ LQVWDOOLQJ XVLQJ RU VWRULQJ WKH SURGXFW RU G PLVXVH RU DFFLGHQW LQ WUDQVLW RU RWKHUZLVH LQFOXGLQJ LQ FDVHV RI WKLUG SDUW DFWLRQV DQG IRUFH PDMHXUH Q QR HYHQW VKDOO 3HHUOHVV ...

Reviews: