Adjustment of Extension Column

• Extension column (

A

) must be fully threaded (six or seven full turns) onto threaded fitting in ceiling plate and then

locked with M5 x 10 mm screw.

WARNING

2

fig. 2.2

fig. 2.3

Skip to step 3 if adjustment is not required.

Remove M8 x 10 mm phillips screw from set hole in extension column (

A

) as shown in fig. 2.1. Slightly loosen

M8 x 10 mm phillips screw in hook slot until inner column is loose. Rotate inner column left and slide down in to
desired hook slot as shown in fig. 2.2 and 2.3. Securely tighten M8 x 10 mm phillips screw in hook slot. Fasten
M8 x 10 mm phillips screw into set hole and inner column and retighten M8 x 10 mm phillips screw in hook slot as
shown in fig. 2.1.

INNER COLUMN

HOOK SLOT

M8 x 10 MM
PHILLIPS SCREW

M8 x 10 MM
PHILLIPS SCREW

• Do not loosen M8 x 10 mm screw to point of

disengagement. Hold inner column securely while
adjusting M8 x 10 mm screw. Tighten fasteners
securely.

WARNING

fig. 2.1

A

INNER COLUMN

M8 x 10 MM
PHILLIPS SCREW

SET HOLE

Summary of Contents for ELPMBC01

Page 1: ...65 8870 Fax 708 865 2941 www peerlessmounts com Maximum UL Load Capacity 500 lb 227 kg Installation and Assembly Adjustable Extension Column Pipe 8 11 Manufactured by Peerless Industries Inc This product is UL Listed It must be installed by a qualified professional installer R ...

Page 2: ...with basic building construction and fully understands these instructions Make sure that the supporting surface will safely support the combined load of the equipment and all attached hard ware and components Never exceed the Maximum UL Load Capacity Always use an assistant or mechanical lifting equipment to safely lift and position equipment Tighten screws firmly but do not overtighten Overtighte...

Page 3: ...ontact Peerless Mounts at 1 800 729 0307 or 708 865 8870 A NOTE Actual parts may appear slightly different than illustrated Outer Column Inner Column M8 x 10 mm phillips screw Parts List Description Qty Part Number A extension column 1 154 2093 Before you start check the parts list to ensure all of the parts shown are included ...

Page 4: ...uded WARNING A Screw extension column to ceiling plate not included as shown in fig 1 1 Align the slot with one of the four holes in the ceiling plate not included and secure extension column with a M5 x 10 mm screw not included as shown in fig 1 2 and detail 1 NOTE Slotted set screws not included are used to jam against the threads of each connecting joint to prevent any excess movement Do not ov...

Page 5: ...sion column A as shown in fig 2 1 Slightly loosen M8 x 10 mm phillips screw in hook slot until inner column is loose Rotate inner column left and slide down in to desired hook slot as shown in fig 2 2 and 2 3 Securely tighten M8 x 10 mm phillips screw in hook slot Fasten M8 x 10 mm phillips screw into set hole and inner column and retighten M8 x 10 mm phillips screw in hook slot as shown in fig 2 ...

Page 6: ...DXWKRUL HG IRU VXFK VHUYLFH RU UHSDLUV E 3HHUOHVV QGXVWULHV QF E WKH IDLOXUH WR XWLOL H SURSHU SDFNLQJ ZKHQ UHWXUQLQJ WKH SURGXFW F LQFRUUHFW LQVWDOODWLRQ RU WKH IDLOXUH WR IROORZ 3HHUOHVVҋ LQVWUXFWLRQV RU ZDUQLQJV ZKHQ LQVWDOOLQJ XVLQJ RU VWRULQJ WKH SURGXFW RU G PLVXVH RU DFFLGHQW LQ WUDQVLW RU RWKHUZLVH LQFOXGLQJ LQ FDVHV RI WKLUG SDUW DFWLRQV DQG IRUFH PDMHXUH Q QR HYHQW VKDOO 3HHUOHVV EH OLDE...