5. FUNCTION SELECTION
5.1 Baud rate
SW number SW1
Function description Baud rate
)
bps
OFF
9600
ON
4800
Table 5-1
notes:
SW1 is ignores when baud rate is store to EEPROM (EEPROM type
only),
baud rate will be refer the EEPROM baud rate status.
5.2 International character set
SW number
Function description
SW2 SW3 SW4 SW5 International
character set(code
20H-7FH)
Code table
(code 80H-FFH)
OFF OFF OFF OFF U.S.A.
PC-437
(USA,standard Europe)
ON OFF OFF OFF FRANCE
PC-850(multilingual)
OFF ON OFF OFF GERMANY
PC-850(multilingual)
ON ON OFF OFF U.K.
PC-850(multilingual)
OFF OFF ON OFF DENMARK I
PC-850(multilingual)
ON OFF ON OFF SWEDEN
PC-850(multilingual)
OFF ON ON OFF ITALY
PC-850(multilingual)
ON ON ON OFF SPAIN
PC-850(multilingual)
OFF OFF OFF ON JAPAN
Katakana
ON OFF OFF ON NORWAY
PC-850(multilingual)
OFF ON OFF ON DENMARK II
PC-850(multilingual)
ON ON OFF ON
SLAVONIC
OFF OFF ON ON
RUSSIA
ON OFF ON ON
Factory define
OFF ON ON ON
Factory define
ON ON ON ON
User define pattern