12. Remove the three screws (silver, 6 mm) that secure the KIT MOT ASSY PH to the KIT GEAR
ASSY PH.
13. Remove the KIT MOT ASSY PH from the KIT GEAR ASSY PH.
Kmy03086EB
12)
12)
12)
13)
KIT MOT ASSY PH
KIT GEAR ASSY PH
COVER TOP
1.
Remove the four screws (silver, self-tapping, 10 mm) and the screw (silver, brimmed, self-tapping,
10 mm) that secure the COVER TOP to the main unit.
2.
Pull the tabs of the COVER TOP outward so that it comes free from the two protrusion of the main unit.
3.
Raise the COVER TOP to disengage the protrusion on the left side of the COVER TOP through the
hole in the main unit, and remove the COVER TOP.
B
1
)
1
)
1
)
1
)
2
)
2
)
3)
-1
1
)
3)
-2
COVER TOP