![Epsolar LandStar LS-EU Series User Manual Download Page 11](http://html1.mh-extra.com/html/epsolar/landstar-ls-eu-series/landstar-ls-eu-series_user-manual_2418508011.webp)
7
4.2 Setting Operation
Load Work Mode Setting
When the controller is powered on, press the setting button to control
the load output. Press the button once, the ON/OFF status will be
changed corresponding. The USB Output is ON only when the Load
Work Mode is at ON status, otherwise, it is OFF.
Battery Type Setting
Press the setting button for more than 5 seconds, battery indicator
LED1, LED2, LED3 will be flashing correspondingly. Then press the
setting button to choose Sealed, Gel, and Flooded battery type, when
you finish choosing, stop pressing the button, the setting is finished till
the digital tube stop flashing. The parameters indicated are shown
below:
Battery type selection
Table4-4
LED1
LED2
LED3
Battery type
○
×
×
Sealed lead acid battery
○
○
×
Gel battery
○
○
○
Flooded battery
“○”LED indicator on
“×”LED indicator off