REMOTE METER DISPLAY:

REMOTE METER OPERATION INSTRUCTION:

the key(from left to right) is: K1-K4, or

Next , Left , Right

, Set

.

The meter display as following order:

Solar panel, battery 1, battery 2, other data as four team data. Use K2 or K3

to check the

data between the teams.

Symbol

is the repeat between the team 1 and team 4. K1 is the key

for repeating the data. Data shows as picture 2.

Data setting instructions: press K4 for setting, K1 for next data and save it. K4 for next data, but
no save. K2 and K3 for modify the data, shows as picture 3.

Backlight instruction: press any key while its connected, the backlight will be on. And set the
backlight timer on setting mode. Backlight options:
OFF: backlight is off all the time

On: backlight is on all the time in any case.

B: 30 backlight on for 30 seconds

B: 20 backlight on for 20 seconds

B: 10 backlight on for 10 seconds

B: 05 backlight on for 5 seconds

Note: backlight timer calculated as the last key press. And backlight has 2 class:
FULL: high bright
HALF: low bright

Data repeat: auto or manual, options as following:
Auto

each team data will repeat every 3 seconds, K1 for next team. K2, K3 for data repeating

in the team.
OFF

data will not repeat automatically, unless press K2 or K3, or K1 for the next team data.

System checking: at any time, press K3+K4, it will check and display the related data
automatically. Details as PICTURE 4. If there is NO, means there is no connection. If the
connections is correct, the related data will be displayed. If no remote temperature sensor
is connected, the meter will show thermometer and NO. if connection is correct, it will show
the data it detects. OPEn means no battery connection or over voltage, the data will be
displayed while the connection is right.

Data erase to 0: at any time, press K1+K2

the data will be erased to 0, such as max, min,

Ah. AH accumulate from 0.

Summary of Contents for EPIPDB-COM series

Page 1: ...TECHNICAL INFORMATION Setpoint Sealed battery Flooded battery Gel battery Regulation voltage 14 2V 14 4V 14 6V Boost voltage 14 4V 14 6V 14 8V Float voltage 13 7V 13 7V 13 7V Maximum solar voltage 30...

Page 2: ...Local temp sensor Measures ambient temperature Battery regulation is adjusted accordingly For battery 1 Provides charging battery status and errors For battery 2 Provides charging battery status and...

Page 3: ...tage you want for battery 1 the controller will automatically calculate the rest for battery 2 Number shows Battery 1 charging Battery 2 charging 0 0 100 1 10 90 2 20 80 3 30 70 4 40 60 5 50 50 6 60 4...

Page 4: ...check the PV and battery and make sure that they are in correct connection 2 LED slowly flashing fully charged 3 LED ON on charging 4 LED frequent flashing no charging and there is battery 5 LED OFF n...

Page 5: ...econds B 10 backlight on for 10 seconds B 05 backlight on for 5 seconds Note backlight timer calculated as the last key press And backlight has 2 class FULL high bright HALF low bright Data repeat aut...